Oil Pressure Switching Valve Inspection
INSPECT OIL PRESSURE SWITCHING VALVE ASSEMBLY
Oil Pressure Switching Valve -- Inspection |
1. INSPECT OIL PRESSURE SWITCHING VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 20°C (68°F)
| 13 to 17 Ω
|
If the result is not as specified, replace the oil pressure switching valve assembly.
Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2 and check that the operating sound of the oil pressure switching valve can be head.
- NOTICE:
- These tests must be performed within 10 seconds to prevent the coil from burning out.
- Always turn the voltage on and off on the battery side, not the oil pressure switching valve side.
If the result is not as specified, replace the oil pressure switching valve.