Fuel Pump (For 5 Door) -- Inspection |
1. INSPECT FUEL PUMP |
Inspect the resistance of the fuel pump.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 0.2 to 3.0 Ω
Inspect the operation of the fuel pump.
Connect the positive (+) lead of the battery to terminal 1 of the connector and the negative (-) lead to terminal 2. Check that the fuel pump operates.
If the result is not as specified, replace the fuel pump.Text in Illustration *a Component without harness connected
(Fuel Pump)- NOTICE:
- These tests must be performed within 10 seconds to prevent the coil from burning out.
- Keep the fuel pump as far away from the battery as possible.
- Always turn the voltage on and off on the battery side, not the fuel pump side.
![]() |