Common Rail -- Inspection |
1. INSPECT COMMON RAIL ASSEMBLY |
Inspect the fuel pressure sensor.
Text in Illustration *a Component without harness connected
(Fuel Pressure Sensor)Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 5 (PR) - 4 (E2) 25°C (77°F) 16.4 kΩ or less 2 (PR2) - 3 (E2S) 16.4 kΩ or less 6 (VC) - 5 (PR) 3 kΩ or less 1 (VCS) - 2 (PR2) 3 kΩ or less
![]() |
Inspect the pressure discharge valve.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 0.42 to 0.52 Ω
- HINT:
- The temperature indicated in "Condition" is the temperature of the pressure discharge valve.