Fuel Filter (For Engine Room Side) -- Inspection |
1. INSPECT FUEL HEATER ASSEMBLY (w/ Fuel Heater) |
Measure the resistance according to the value(s) in the table below.
Measure the resistance between terminal 2 and the heater body.
Apply a vacuum of 29 to 40 kPa (218 to 300 mmHg, 8.56 to 11.8 in.Hg) or higher to the vacuum switch port.
- Standard Resistance:
Tester Connection Condition Specified Condition 2 - Heater body 20°C (68°F) 0.5 to 2.0 Ω
If the result is not as specified, replace the fuel heater assembly.Text in Illustration *1 Heater Body
![]() |
2. INSPECT FUEL FILTER CAP ASSEMBLY (w/ Clogging Switch) |
Inspect the clogging switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) Below 1 Ω