Heated Oxygen Sensor -- Installation |
1. INSTALL HEATED OXYGEN SENSOR |
Using SST, install the heated oxygen sensor.
- SST
- 09224-00011
- Torque:
- Specified tightening torque:
- 44 N*m{449 kgf*cm, 32 ft.*lbf}
Text in Illustration *a Fulcrum Length - HINT:
- Make sure SST and the wrench are connected in a straight line.
- Calculate the torque wrench reading when changing the fulcrum length of the torque wrench (LandCruiser RM000003YMD00TX.html).
- When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 180 mm (7.09 in.)): 38 N*m (384 kgf*cm, 28 ft.*lbf)
![]() |
Attach the wire harness clamp.
Connect the heated oxygen sensor connector.