Heated Oxygen Sensor -- Inspection |
1. INSPECT HEATED OXYGEN SENSOR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (HT1B) - 2 (+B) 20°C (68°F) 5 to 8 Ω 1 (HT1B) - 4 (E2) Always 10 kΩ or higher
If the result is not as specified, replace the heated oxygen sensor.Text in Illustration *a Component without harness connected
(Heated Oxygen Sensor)
![]() |