Camshaft Position Sensor Installation


  1. INSTALL CAMSHAFT POSITION SENSOR (for Intake Side)

  2. INSTALL CAMSHAFT POSITION SENSOR (for Exhaust Side)

  3. INSTALL INTAKE AIR CONNECTOR

  4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE

Camshaft Position Sensor -- Installation



1. INSTALL CAMSHAFT POSITION SENSOR (for Intake Side)
  1. Apply a light coat of engine oil to the O-ring of the camshaft position sensor.

  1. Install the camshaft position sensor with the bolt.

    Torque:
    9.0 N*m{92 kgf*cm, 80 in.*lbf}
    NOTICE:
    1. When reusing the camshaft position sensor, inspect the O-ring.
    2. Make sure that the O-ring is not cracked or jammed when installing the camshaft position sensor.
  1. Connect the camshaft position sensor connector.



2. INSTALL CAMSHAFT POSITION SENSOR (for Exhaust Side)
  1. Apply a light coat of engine oil to the O-ring of the camshaft position sensor.

  1. Install the camshaft position sensor with the bolt.

    Torque:
    9.0 N*m{92 kgf*cm, 80 in.*lbf}
    NOTICE:
    1. When reusing the camshaft position sensor, inspect the O-ring.
    2. Make sure that the O-ring is not cracked or jammed when installing the camshaft position sensor.
  1. Connect the camshaft position sensor connector.



3. INSTALL INTAKE AIR CONNECTOR
  1. Install the intake air connector with the 3 bolts.

    Torque:
    8.0 N*m{82 kgf*cm, 71 in.*lbf}
  1. Tighten the hose clamp.

    Torque:
    5.0 N*m{51 kgf*cm, 44 in.*lbf}
  1. Connect the vacuum hose.

  1. Connect the No. 2 ventilation hose.

  1. Connect the vacuum hose to the air pressure sensor.

  1. Connect the air pressure sensor connector.

  1. Attach the wire harness and vacuum hose to the intake air connector.



4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE


    Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.2Tr-Fe Engine Control.Sfi System.Camshaft Position Sensor  Installation
  1. Install the air cleaner cap sub-assembly with air cleaner hose and align its matchmark with the matchmark of the intake air connector as shown in the illustration.

    Text in Illustration
    *a
    Upper
    *b
    Front
    *c
    Matchmark
  1. Tighten the hose clamp.

    NOTICE:
    Check that the air cleaner hose is securely installed.
  1. Attach the 4 clamps.

  1. Attach the 3 clamps and connect the intake mass air flow meter connector.