Intake Air Temperature Sensor Inspection
INSPECT INTAKE AIR TEMPERATURE SENSOR
Intake Air Temperature Sensor -- Inspection |
1. INSPECT INTAKE AIR TEMPERATURE SENSOR |
Measure the resistance according to the value(s) in the table below.
Text in Illustration*a
| Component without harness connected (Intake Air Temperature Sensor)
| *b
| Resistance
|
*c
| Temperature
| *d
| Acceptable Range
|
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 20°C (68°F)
| 2.21 to 2.65 kΩ
|
60°C (140°F)
| 0.54 to 0.62 kΩ
|
- CAUTION:
- Do not put your hands in the water warmed up during the inspection.
- Touching the hot water may result in burns.
- NOTICE:
- When checking the intake air temperature sensor in water, do not allow water to contact the terminals. After completing the check, dry the intake air temperature sensor.
If the result is not as specified, replace the intake air temperature sensor.