Solar Sensor (For Automatic Air Conditioning System) Inspection


  1. INSPECT SOLAR SENSOR

Solar Sensor (For Automatic Air Conditioning System) -- Inspection



1. INSPECT SOLAR SENSOR


Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.Air Conditioning.Solar Sensor (For Automatic Air Conditioning System).Solar Sensor (For Automatic Air Conditioning System)  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    NOTICE:
    Connect the ohmmeter's negative (-) lead to terminal 1 and positive (+) lead to terminal 2.
    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Sensor is subjected to electric light
    Below 10 kΩ
    Sensor is covered with a cloth
    10 kΩ or higher
    If the result is not as specified, replace the solar sensor.
    NOTICE:
    The connection procedure for a digital tester, such as a TOYOTA electrical tester, is shown above. When using an analog tester, connect the negative (-) lead to terminal 2 and the positive (+) lead to terminal 1.
    HINT:
    1. As the inspection light is moved away from the sensor, the resistance increases.
    2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the A/C solar sensor.