Vacuum Pump (For 5L-E) -- Installation |
1. INSTALL VACUUM PUMP ASSEMBLY |
Align the matchmarks and install the vacuum pump to the generator with the 4 bolts.
- Torque:
- 7.8 N*m{80 kgf*cm, 69 in.*lbf}
![]() |
2. INSTALL GENERATOR WITH VACUUM PUMP ASSEMBLY |
- HINT:
- Refer to the instructions for installation of the generator with vacuum pump (Toyota Fortuner RM0000014PF00IX.html).
3. CHECK VACUUM PUMP ASSEMBLY |
Disconnect the vacuum hose from the vacuum pump.
Connect the hose of a vacuum gauge to the pump.
![]() |
Insert a plug into the other hose of the gauge.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, measure the negative pressure of the pump.
- Standard negative pressure:
- More than 86.7 kPa (650 mmHg, 26 in.Hg)
Remove the gauge from the pump.
Connect the hose to the pump with the clip.