Exhaust Pipe -- Installation |
1. INSTALL FRONT EXHAUST PIPE ASSEMBLY |
Install the front pipe to the pipe support.
Install a new gasket and the front pipe to the exhaust manifold.
Install the front pipe with the 2 nuts.
- Torque:
- 62 N*m{632 kgf*cm, 46 ft.*lbf}
2. INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY |
Install the front pipe to the pipe support.
Install 2 new gaskets and the front pipe to the exhaust manifold.
Install the front pipe with the 2 bolts and 2 nuts.
- Torque:
- 48 N*m{489 kgf*cm, 35 ft.*lbf}for nut
- 62 N*m{632 kgf*cm, 46 ft.*lbf}for bolt
- NOTICE:
- Do not reuse the gasket.
3. INSTALL CENTER EXHAUST PIPE ASSEMBLY |
Using a vernier caliper, measure the free length of the compression spring.
- Minimum length:
- 40.5 mm (1.5945 in.)
![]() |
Install the center pipe to the 3 pipe supports.
Install a new gasket to the front exhaust pipe.
- HINT:
- Using a plastic-faced hammer, uniformly strike the gasket so that the gasket and front exhaust pipe fit properly.
- NOTICE:
- Be careful with the installation direction of the gasket.
- Do not reuse the gasket.
- To ensure a proper seal, do not use the tailpipe to force the gasket onto the front exhaust pipe.
Install the exhaust pipe with the 2 bolts and 2 springs.
- Torque:
- 43 N*m{438 kgf*cm, 32 ft.*lbf}
4. INSTALL TAILPIPE ASSEMBLY |
Install a new gasket on the center exhaust pipe.
Install the tailpipe with the 2 bolts.
- Torque:
- 48 N*m{489 kgf*cm, 35 ft.*lbf}
- NOTICE:
- Do not reuse the gasket.
5. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2) |
![]() |
Using SST, install the sensor to the front exhaust pipe.
- SST
- 09224-00010
- Torque:
- 40 N*m{408 kgf*cm, 30 ft.*lbf} for use with SST
- 44 N*m{449 kgf*cm, 32 ft.*lbf} for use without SST
- HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).
Connect the sensor connector.
6. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2) |
![]() |
Using SST, install the sensor to the front exhaust pipe.
- SST
- 09224-00010
- Torque:
- 40 N*m{408 kgf*cm, 30 ft.*lbf} for use with SST
- 44 N*m{449 kgf*cm, 32 ft.*lbf} for use without SST
- HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).
Connect the sensor connector.
7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
8. CHECK FOR EXHAUST GAS LEAKS |