Room Temperature Sensor (For Automatic Air Conditioning System) Inspection
INSPECT ROOM TEMPERATURE SENSOR
Room Temperature Sensor (For Automatic Air Conditioning System) -- Inspection |
1. INSPECT ROOM TEMPERATURE SENSOR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 10°C (50°F)
| 3.00 to 3.73 kΩ
|
15°C (59°F)
| 2.45 to 2.88 kΩ
|
20°C (68°F)
| 1.95 to 2.30 kΩ
|
25°C (77°F)
| 1.60 to 1.80 kΩ
|
30°C (86°F)
| 1.28 to 1.47 kΩ
|
35°C (95°F)
| 1.00 to 1.22 kΩ
|
40°C (104°F)
| 0.80 to 1.00 kΩ
|
45°C (113°F)
| 0.65 to 0.85 kΩ
|
50°C (122°F)
| 0.50 to 0.70 kΩ
|
55°C (131°F)
| 0.44 to 0.60 kΩ
|
60°C (140°F)
| 0.36 to 0.50 kΩ
|
If the result is not as specified, replace the room temperature sensor.
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (refer to the graph).