Vacuum Switching Valve Installation


  1. INSTALL VACUUM SWITCHING VALVE (for EGR Cut)

  2. INSTALL VACUUM TRANSMITTING HOSE ASSEMBLY

  3. INSTALL NO. 2 VACUUM TRANSMITTING HOSE ASSEMBLY

  4. INSTALL MANIFOLD STAY WITH VACUUM SWITCHING VALVE

Vacuum Switching Valve -- Installation



1. INSTALL VACUUM SWITCHING VALVE (for EGR Cut)
  1. Install the vacuum switching valve to the manifold stay with the screw.

    Torque:
    3.5 N*m{36 kgf*cm, 31 in.*lbf}


2. INSTALL VACUUM TRANSMITTING HOSE ASSEMBLY


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.2Kd-Ftv Emission Control.Vacuum Switching Valve.Vacuum Switching Valve  Installation
  1. Install the vacuum transmitting hose shown in the illustration.

    Text in Illustration
    *1
    Yellow Paint


3. INSTALL NO. 2 VACUUM TRANSMITTING HOSE ASSEMBLY


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.2Kd-Ftv Emission Control.Vacuum Switching Valve.Vacuum Switching Valve  Installation
  1. Install the No. 2 vacuum transmitting hose to the vacuum switching valve shown in the illustration.

    Text in Illustration
    *1
    Pink Paint


4. INSTALL MANIFOLD STAY WITH VACUUM SWITCHING VALVE


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Install the manifold stay with vacuum switching valve with the 2 bolts and connect the vacuum transmitting hose.

    Torque:
    19 N*m{194 kgf*cm, 14 ft.*lbf}
    NOTICE:
    Be sure to securely connect the vacuum transmitting hose.


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.2Kd-Ftv Emission Control.Vacuum Switching Valve.Vacuum Switching Valve  Installation
  1. Connect the 2 vacuum transmitting hoses.

    Text in Illustration
    *1
    Yellow Paint
    *2
    Pink Paint
    NOTICE:
    1. Be sure to securely connect the vacuum transmitting hoses.
    2. Make sure the vacuum transmitting hoses' color matches the connection areas' color.
  1. Connect the vacuum switching valve connector.