Power Window Control System (W/ Jam Protection Function) Auto Up Operation Does Not Fully Close Power Window (Jam Protection Function Is Activated)
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
RESET POWER WINDOW REGULATOR MOTOR ASSEMBLY
CHECK POWER WINDOW REGULATOR ASSEMBLY
POWER WINDOW CONTROL SYSTEM (w/ Jam Protection Function) - Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) |
DESCRIPTION
If the door glass or the power window regulator motor does not operate smoothly, the jam protection function may be triggered automatically, resulting in the AUTO UP function being unable to fully close the window.- HINT:
- The jam protection function is only available on the driver side power window.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.RESET POWER WINDOW REGULATOR MOTOR ASSEMBLY |
Reset the power window regulator motor.
Check that the power window AUTO UP / DOWN function operates normally.
- OK:
- AUTO UP / DOWN function operates normally.
2.CHECK POWER WINDOW REGULATOR ASSEMBLY |
Remove the door glass.
Operate the front door window regulator using the switch.
Check that the power window regulator operates smoothly.
- OK:
- Power window regulator operates smoothly.
| REPLACE FRONT DOOR WINDOW REGULATOR SUB-ASSEMBLY |
|
|
OK |
|
|
|
REPLACE FRONT DOOR GLASS RUN RH |
|