Generator -- Inspection |
1. INSPECT GENERATOR ROTOR ASSEMBLY |
Check the rotor for an open circuit.
Measure the resistance between the slip rings.
- Standard resistance:
- 1.85 to 2.25 Ω at 20°C (68°F)
![]() |
Check if the rotor is grounded.
Measure the resistance between the slip ring and rotor.
- Standard resistance:
- 10 kΩ or higher
![]() |
Check that the slip rings are not rough or scored.
If rough or scored, replace the rotor assembly.
Using a vernier caliper, measure the slip ring diameter.
- Standard diameter:
- 14.2 to 14.4 mm (0.559 to 0.567 in.)
- Minimum diameter:
- 14.0 mm (0.551 in.)
![]() |
2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the exposed brush length.
- Standard exposed length:
- 10.5 mm (0.413 in.)
- Minimum exposed length:
- 4.5 mm (0.177 in.)
3. INSPECT GENERATOR DRIVE END FRAME BEARING |
Check that the bearing is not rough or worn.
If necessary, replace the bearing.
![]() |
4. INSPECT GENERATOR ROTOR BEARING |
Check that the bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
![]() |
5. INSPECT GENERATOR PULLEY WITH CLUTCH |
When rotating the pulley, check that it turns clockwise and that it does not turn counterclockwise.
If the result is not as specified, replace the generator pulley with clutch.