Generator Inspection


  1. INSPECT GENERATOR ROTOR ASSEMBLY

  2. INSPECT GENERATOR STATOR SUB-ASSEMBLY WITH RECTIFIER

  3. INSPECT BRUSH

Generator -- Inspection



1. INSPECT GENERATOR ROTOR ASSEMBLY


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Check the rotor for an open circuit.

    1. Measure the resistance between the slip rings.

      Standard resistance:
      1.8 to 2.8 Ωat 20°C (68°F)
      If the result is not as specified, replace the rotor assembly.


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Check if the rotor is grounded.

    1. Measure the resistance between the slip ring and rotor.

      Standard resistance:
      10 kΩ or higher
      If the result is not as specified, replace the rotor assembly.
  1. Check that the slip rings are not rough or scored.
    If rough or scored, replace the rotor assembly.



    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Using a vernier caliper, measure the slip ring diameter.

    Standard diameter:
    15.3 to 15.5 mm (0.602 to 0.610 in.)
    Minimum diameter:
    14.9 mm (0.587 in.)
    If the diameter is less than the minimum, replace the rotor assembly.


2. INSPECT GENERATOR STATOR SUB-ASSEMBLY WITH RECTIFIER



Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.1Kd-Ftv Charging.Generator.Generator  Inspection

HINT:
For terminal positions of the generator stator, refer to the illustration.


    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Inspect the positive (+) rectifier.

    HINT:
    Inspect the positive terminal after pulling it up.

    1. Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.

    2. Reverse the polarity of the tester probes and repeat the step above.

    3. Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
      If the result is not as specified, replace the generator stator sub-assembly with rectifier.



    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Inspect the negative (-) rectifier.

    1. Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.

    2. Reverse the polarity of the tester probes and repeat the step above.

    3. Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
      If the result is not as specified, replace the generator stator sub-assembly with rectifier.



    Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50
  1. Inspect the stator coil for an open circuit.

    1. Measure the resistance between the rectifier terminals.

      Standard resistance:
      Below 1 Ω
      If the result is not as specified, replace the generator stator sub-assembly with rectifier.


3. INSPECT BRUSH


Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.1Kd-Ftv Charging.Generator.Generator  Inspection
  1. Using a vernier caliper, measure the exposed brush length.

    Standard exposed length on new brush:
    13.2 mm (0.520 in.)
    Minimum exposed length:
    6.0 mm (0.236 in.)
    If the exposed length is less than the minimum, replace the voltage regulator sub-assembly with brush.