Thermostat -- Inspection |
1. INSPECT WATER INLET HOUSING WITH THERMOSTAT |
![]() |
- HINT:
- The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in water, and then heat the water gradually.
![]() |
Check the valve opening temperature of the thermostat.
- Standard valve opening temperature:
- 80 to 84°C (176 to 183°F)
Check the valve lift.
- Standard valve lift:
- 8.0 mm (0.31 in.) or more at 95°C (203°F)
![]() |
Check that the valve is fully closed when the thermostat is at low temperature (below 40°C (104°F)).
If not fully closed, replace the water inlet housing with thermostat.