Ignition Switch -- Inspection |
1. INSPECT IGNITION SWITCH ASSEMBLY |
![]() |
Measure the resistance of the switch.
- Standard resistance:
Tester Connection Switch Condition Specified Condition - LOCK 10 kΩ or higher 2 (ACC) - 4 (AM1) ACC Below 1 Ω 1 (IG1) - 4 (AM1)
2 (ACC) - 4 (AM1)
5 (AM2) - 6 (IG2)ON Below 1 Ω 1 (IG1) - 4 (AM1)
2 (ACC) - 4 (AM1)
5 (AM2) - 6 (IG2)
5 (AM2) - 7 (ST2)START Below 1 Ω