Generator -- Removal |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Toyota Fortuner RM000002HD2002X.html).
2. REMOVE AIR CLEANER ASSEMBLY |
![]() |
Disconnect the MAF meter connector and remove the clamp.
Loosen the hose clamp of the compressor inlet elbow.
Remove the 2 bolts and air cleaner.
3. REMOVE FAN AND GENERATOR V BELT |
Rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.
4. REMOVE GENERATOR ASSEMBLY |
![]() |
Disconnect the terminal cap.
Remove the nut and generator wire.
Disconnect the generator connector.
Remove the 2 bolts and generator.