Generator -- Installation |
1. INSTALL GENERATOR ASSEMBLY |
Install the generator with the 2 bolts.
- Torque:
- 43 N*m{438 kgf*cm, 32 ft.*lbf}
![]() |
Install the generator wire with the bolt and nut.
- Torque:
- 9.8 N*m{100 kgf*cm, 87 in.*lbf}
Attach the terminal cap.
Connect the connector.
2. INSTALL DRIVE BELT |
Install the drive belt to all the pulleys except the drive belt tensioner pulley.
![]() |
Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and then install the drive belt to the tensioner pulley.
- NOTICE:
- The backside of the drive belt should face the tensioner pulley.
- Check that the drive belt is properly set to each pulley.
After a new belt has been installed, check that the tensioner indicator mark is within range A shown in the illustration.
![]() |
3. INSTALL INTAKE AIR CONNECTOR AND AIR CLEANER ASSEMBLY |
Install the air cleaner and intake air connector assembly with the 4 bolts, and tighten the hose clamp.
- Torque:
- 14 N*m{143 kgf*cm, 10 ft.*lbf}for air cleaner
- 8.0 N*m{82 kgf*cm, 71 in.*lbf}for intake air connector
- 5.0 N*m{51 kgf*cm, 44 in.*lbf}for hose clamp
![]() |
Connect the MAF meter connector and harness clamps.
Connect the No. 2 ventilation hose.
Connect the vacuum hose.
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Toyota Fortuner RM000002HD2000X.html).