Ecd System Pre-Heating Control Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK GLOW INDICATOR LIGHT
CHECK GLOW PLUG (INSTALLATION)
INSPECT GLOW PLUG
CHECK FOR INDICATOR LIGHTING TIME AND AFTER GLOW TIME
READ OUTPUT DTC
INSPECT GLOW RELAY
CHECK ECM (SREL VOLTAGE)
CHECK HARNESS AND CONNECTOR (GLOW RELAY - ECM AND BODY GROUND)
CHECK HARNESS AND CONNECTOR (GLOW RELAY - GLOW PLUG AND BATTERY)
CHECK ECM (GIND VOLTAGE)
CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER)
CHECK FUSE (MET)
CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY)
ECD SYSTEM - Pre-heating Control Circuit |
DESCRIPTION
When the ignition switch turns ON, the ECM calculates the glow indicator lighting time/heating corresponding to the coolant temperature at that time and turns on the glow indicator light/glow plug relay.As ceramic is used for glow plug material, the current control is not performed.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK GLOW INDICATOR LIGHT |
Turn the ignition switch ON.
Check that the glow indicator light comes on.
- OK:
- The glow indicator light remains on for 0.5 seconds or more and then goes off.
2.CHECK GLOW PLUG (INSTALLATION) |
Check that the glow plug and glow plug wire are securely installed.
- OK:
- The glow plug and glow plug wire are securely installed.
Measure the resistance of the glow plug.
- Standard resistance:
- 0.72 Ω at 20°C (68°F)
- HINT:
- The higher the temperature, the smaller the resistance becomes and vice versa.
4.CHECK FOR INDICATOR LIGHTING TIME AND AFTER GLOW TIME |
Read the DTC (Toyota Fortuner RM000000VR6004X.html).
- Result:
Result
| Proceed to
|
DTC is not output
| A
|
DTC is output
| B
|
Measure the resistance of the glow relay.
- Standard resistance:
Tester Connection
| Specified Condition
|
3 - 5
| 10 kΩ or higher (No continuity)
|
3 - 5
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
|
7.CHECK ECM (SREL VOLTAGE) |
Turn the ignition switch to the START position.
Measure the voltage of the ECM connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E23-2 (SREL) - E20-14 (E1)
| Cranking
| 9 to 14 V
|
8.CHECK HARNESS AND CONNECTOR (GLOW RELAY - ECM AND BODY GROUND) |
Disconnect the E23 ECM connector.
Disconnect the glow relay from the engine room relay block.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Specified Condition
|
E23-2 (SREL) - Relay block glow relay terminal 2
| Below 1 Ω
|
Relay block glow relay terminal 1 - Body ground
| Below 1 Ω
|
E23-2 (SREL) or relay block glow relay terminal 2 - Body ground
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
9.CHECK HARNESS AND CONNECTOR (GLOW RELAY - GLOW PLUG AND BATTERY) |
Disconnect the battery negative (-) cable.
Disconnect the battery positive (+) cable.
Remove the glow relay from the engine room relay block.
Disconnect the glow plug wire.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Specified Condition
|
Relay block glow relay terminal 3 - Glow plug wire
| Below 1 Ω
|
Relay block glow relay terminal 5 - Battery positive (+) terminal
| Below 1 Ω
|
- NOTICE:
- After reconnecting the battery cable, the radio and clock should be adjusted as they were previously.
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|
10.CHECK ECM (GIND VOLTAGE) |
Disconnect the E22 ECM connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connectors.
- Standard voltage:
Tester Connection
| Specified Condition
|
E22-1 (GIND) - E20-14 (E1)
| 9 to 14 V
|
11.CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER) |
Disconnect the C10 combination meter connector.
Disconnect the E22 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Specified Condition
|
C10-40 - E22-1 (GIND)
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
Remove the MET fuse from the instrument panel junction block.
Measure the resistance of the fuse.
- Standard resistance:
Tester Connection
| Specified Condition
|
MET fuse
| Below 1 Ω
|
| CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSE |
|
|
13.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY) |
Disconnect the C10 combination meter connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Specified Condition
|
C10-21 - Body ground
| 9 to 14 V
|
| REPLACE COMBINATION METER |
|
|