Ecd System -- Diagnosis System



DESCRIPTION
When troubleshooting Multiplex OBD (M-OBD) vehicles, the vehicle must be connected to the intelligent tester. Various data output from the vehicle's Engine Control Module (ECM) can then be read.
The Malfunction Indicator Lamp (MIL) is illuminated when the vehicle's onboard computer detects a malfunction in the computer itself or in drive system components. In addition, the applicable Diagnostic Trouble Codes (DTCs) are recorded in the ECM memory (Toyota Fortuner RM000000VQT004X.html).
If the malfunction does not reoccur, the MIL stays illuminated until the ignition switch is turned OFF, and the MIL turns OFF when the engine is started. However the DTCs remain recorded in the ECM memory.
To check DTCs, connect the intelligent tester to the Data Link Connector 3 (DLC3) on the vehicle or connect terminals TC and CG on the DLC3 (DTCs will be displayed in the combination meter).
Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.5L-E Engine Control System.Ecd System.Ecd System  Diagnosis System
Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.5L-E Engine Control System.Ecd System.Ecd System  Diagnosis System

NORMAL MODE AND CHECK MODE
The diagnosis system operates in "normal mode" during normal vehicle use. In normal mode, "2 trip detection logic" is used to ensure accurate detection of malfunctions. "Check mode" is also available to technicians as an option. In check mode, "1 trip detection logic" is used for simulating malfunction symptoms and increasing the system's ability to detect malfunctions, including intermittent malfunctions (Toyota Fortuner RM000000VR7004X.html).

2 TRIP DETECTION LOGIC
When a malfunction is first detected, the malfunction is temporarily stored in the ECM memory (1st trip). If the same malfunction is detected during the subsequent drive cycle, the MIL is illuminated (2nd trip).

FREEZE FRAME DATA
Freeze frame data records the engine conditions (fuel system, calculated engine load, engine coolant temperature, fuel trim, engine speed, vehicle speed, etc.) when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

CHECK DLC3
The vehicle's ECM uses ISO 14230 (M-OBD) communication protocol. The terminal arrangement of the DLC3 complies with ISO 15031-03 and matches the ISO 14230 format.
Toyota Fortuner. Ggn50, 60 Kun51, 61 Tgn51 Lan50.5L-E Engine Control System.Ecd System.Ecd System  Diagnosis System

Symbols (Terminal No.)
Terminal Description
Condition
Specified Condition
SIL (7) - SG (5)
Bus "+" line
During transmission
Pulse generation
CG (4) - Body ground
Chassis ground
Always
Below 1 Ω
SG (5) - Body ground
Signal ground
Always
Below 1 Ω
BAT (16) - Body ground
Battery positive
Always
9 to 14 V
HINT:
Connect the cable of the intelligent tester to the DLC3, turn the ignition switch ON and attempt to use the intelligent tester. If the display indicates that a communication error has occurred, there is a problem either with the vehicle or with the tester.
  1. If communication is normal when the tester is connected to another vehicle, inspect the DLC3 on the original vehicle.
  2. If communication is still not possible when the tester is connected to another vehicle, the problem is probably in the tester itself. Consult the Service Department listed in the tester's instruction manual.

INSPECT BATTERY VOLTAGE
If the voltage is below 11 V, recharge or replace the battery before proceeding.
Battery voltage:
11 to 14 V

CHECK MIL
  1. The MIL illuminates when the ignition switch is turned ON and the engine is not running.

    HINT:
    If the MIL is not illuminated, check the MIL circuit (Toyota Fortuner RM000000ZQY00EX.html).
  2. When the engine is started, the MIL should turn off. If the lamp remains illuminated, the diagnosis system has detected a malfunction or abnormality in the system.