Sfi System - Acis Control Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST USING GTS (OPERATE VACUUM SWITCHING VALVE FOR ACIS)
CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR ACIS) - INTAKE AIR CONTROL VALVE, INTAKE MANIFOLD)
INSPECT INTAKE MANIFOLD (INTAKE AIR CONTROL VALVE)
INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS)
CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR ACIS) - ECM AND NO. 1 INTEGRATION RELAY)
SFI SYSTEM - ACIS Control Circuit
DESCRIPTION
This circuit opens and closes the Intake Air Control Valve (IACV) in response to the engine load in order to increase the intake efficiency (ACIS: Acoustic Control Induction System).

WIRING DIAGRAM
Refer to DTC P0660 ().
INSPECTION PROCEDURE
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.PERFORM ACTIVE TEST USING GTS (OPERATE VACUUM SWITCHING VALVE FOR ACIS) |
Disconnect the vacuum hose from port F on the vacuum switching valve (for ACIS).
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Intake Control.
Operate the vacuum switching valve for ACIS.
Check the vacuum switching valve air flow when switching the vacuum switching valve.
- OK:
Test Condition | Specified Condition |
Vacuum switching valve is ON | Air from port E flows out through port F |
Vacuum switching valve is OFF | Air from port E flows out through air filter |
Text in Illustration*a | VSV is ON |
*b | VSV is OFF |
*c | Air |
2.CHECK VACUUM HOSES (VACUUM SWITCHING VALVE (FOR ACIS) - INTAKE AIR CONTROL VALVE, INTAKE MANIFOLD) |
| REPAIR OR REPLACE VACUUM HOSES |
|
|
3.INSPECT INTAKE MANIFOLD (INTAKE AIR CONTROL VALVE) |
Inspect the intake air control valve ().
| REPLACE INTAKE MANIFOLD ()
|
|
|
OK | |
| |
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE ()
|
|
4.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) |
Inspect the vacuum switching valve assembly (for ACIS) ().
| REPLACE VACUUM SWITCHING VALVE ASSEMBLY (FOR ACIS) ()
|
|
|
5.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR ACIS) - ECM AND NO. 1 INTEGRATION RELAY) |
Disconnect the vacuum switching valve (for ACIS) connector.
Disconnect the ECM connector.
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHDTester Connection | Condition | Specified Condition |
C129-2 - C46-62 (ACIS) | Always | Below 1 Ω |
C129-1 - 1B-4 | Always | Below 1 Ω |
C129-2 or C46-62 (ACIS) - Body ground | Always | 10 kΩ or higher |
C129-1 or 1B-4 - Body ground | Always | 10 kΩ or higher |
for LHDTester Connection | Condition | Specified Condition |
C129-2 - C45-62 (ACIS) | Always | Below 1 Ω |
C129-1 - 1B-4 | Always | Below 1 Ω |
C129-2 or C45-62 (ACIS) - Body ground | Always | 10 kΩ or higher |
C129-1 or 1B-4 - Body ground | Always | 10 kΩ or higher |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|