Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - 3UR-FE ENGINE CONTROL
HEATED OXYGEN SENSOR - INSPECTION
1. INSPECT HEATED OXYGEN SENSOR |

Measure the heater resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (HT1B) - 2 (+B)
(for Bank 1)20°C (68°F) 11 to 16 Ω 1 (HT2B) - 2 (+B)
(for Bank 2)
*A | for Bank 1 |
*B | for Bank 2 |
*a | Component without harness connected (Heated Oxygen Sensor) |
If the result is not as specified, replace the sensor.