Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - AB60F AUTOMATIC TRANSMISSION / TRANSAXLE
VALVE BODY ASSEMBLY - INSPECTION
1. INSPECT SHIFT SOLENOID VALVE SL1 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1Battery negative (-) → Terminal 2Valve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
2. INSPECT SHIFT SOLENOID VALVE S1 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S1 connectorBattery negative (-) → Shift solenoid valve S1 bodyValve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
3. INSPECT SHIFT SOLENOID VALVE S2 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S2 connectorBattery negative (-) → Shift solenoid valve S2 bodyValve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
4. INSPECT SHIFT SOLENOID VALVE S3 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 20°C (68°F) 11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S3 connectorBattery negative (-) → Shift solenoid valve S3 bodyValve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
5. INSPECT SHIFT SOLENOID VALVE S4 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve S4 connectorBattery negative (-) → Shift solenoid valve S4 bodyValve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
6. INSPECT SHIFT SOLENOID VALVE SL2 |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 1Battery negative (-) → Terminal 2Valve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
7. INSPECT SHIFT SOLENOID VALVE SR |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Shift solenoid valve SR connectorBattery negative (-) → Shift solenoid valve SR bodyValve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
8. INSPECT SHIFT SOLENOID VALVE SLT |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2Battery negative (-) → Terminal 1Valve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.
9. INSPECT SHIFT SOLENOID VALVE SLU |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Shift solenoid valve Terminal 2Battery negative (-) → Terminal 1Valve moves and makes an operating noise
If the result is not as specified, replace the solenoid valve.