Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - AB60F AUTOMATIC TRANSMISSION / TRANSAXLE
SPEED SENSOR - INSTALLATION
1. INSTALL SPEED SENSOR SP2 |

Coat a new O-ring with ATF and install it to the sensor.
Install the sensor with the bolt.
- Torque:
- 5.4 N*m{ 55 kgf*cm, 48 in.*lbf}
Connect the sensor connector.
2. INSTALL SPEED SENSOR NT |

Coat a new O-ring with ATF and install it to the sensor.
Install the sensor with the bolt.
- Torque:
- 5.4 N*m{ 55 kgf*cm, 48 in.*lbf}
Connect the sensor connector.
3. INSTALL FRONT EXHAUST PIPE ASSEMBLY (w/ DPF) |
Install a new gasket and the front exhaust pipe to the monolithic converter RH with 3 new nuts.
- Torque:
- 48 N*m{ 489 kgf*cm, 35 ft.*lbf}

Check the free length.
Using a vernier caliper, measure the free length of the compression spring.
- Free length:
- 43 mm (1.69 in.)
If the free length is less than the minimum, replace the compression spring.
Install a new gasket and connect the front exhaust pipe assembly with the 2 bolts and 2 compression springs.
- Torque:
- 43 N*m{ 438 kgf*cm, 32 ft.*lbf}

Attach the clamp and connect the exhaust gas temperature sensor connector.
*1 | Tape |
*2 | Stopper |
*3 | Clip |
*4 | Paint Mark |
*a | 2 to 7 mm (0.0787 to 0.276 in.) |
- HINT:
- Make sure that the tape is in the position shown in the illustration.
Install 2 new clips to the 2 air hoses.
Connect the 2 air hoses to the front exhaust pipe.
- NOTICE:
Connect the air fuel ratio sensor connector.
4. INSPECT FOR EXHAUST GAS LEAK |