Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - AB60F AUTOMATIC TRANSMISSION / TRANSAXLE

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT NO. 1 TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR)

CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

DTC P2742 Transmission Fluid Temperature Sensor "B" Circuit Low Input

DTC P2743 Transmission Fluid Temperature Sensor "B" Circuit High Input

DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor is on the transmission, just in front of the oil cooler inlet pipeline.


If the ECM detects an abnormally high ATF temperature near this sensor, it illuminates the warning light.


  • HINT:
The temperature of ATF easily rises when towing, climbing hills, in traffic, etc.
If the ATF temperature sensor becomes short-circuited, the signal that indicates that the ATF temperature is 150°C (302°F) or higher is input into the ECM.

Vehicle conditions when the sensor is normal and when the sensor is short-circuited are indicated in the table below.

No. 2 ATF Temperature Sensor StateDetection ConditionSymptomRecovery Condition
Sensor is normalATF temperature more than 150°C (302°F)ATF temperature warning light remains onATF temperature less than 135°C (275°F)*1
ATF temperature more than 130°C (266°F)Shift point too highATF temperature less than 110°C (230°F)
When the conditions (a) and (b) are satisfied.
(a) ATF temperature more than 130°C (266°F)
(b) Engine coolant temperature more than 95°C (203°F)
Lock-up at 3rd gear*2ATF temperature less than 110°C (230°F)*1 and engine coolant temperature more than 95°C (203°F)
Sensor is short-circuitedAny conditions
ATF temperature warning light blinks or message is displayed in combination meter
Shift point too high
Symptoms still occur
Engine coolant temperature more than 95°C (203°F)Lock-up at 3rd gear*2Symptoms still occur
  • HINT:
  • *1: When ATF temperature is in the normal range, it decreases to less than 135°C (275°F) within 5 minutes with the shift lever in P or N in an idling state.
  • *2: When ATF temperature is normal, transmission lock-up occurs in 5th or 6th gear with the shift lever in D or S with the S6 range selected, in 5th gear with the shift lever in S with the S5 range selected, and 4th gear with the shift lever in S with the S4 range selected.
DTC CodeDTC Detection ConditionTrouble Area
P2742No. 2 ATF temperature sensor resistance is less than 25 Ω (0.046 V) for 0.5 seconds or more (1 trip detection logic).
Short in No. 2 ATF temperature sensor circuit
No. 2 ATF temperature sensor (No. 1 transmission wire)
ECM
P2743When 15 minutes or more have elapsed after engine is started, No. 2 ATF temperature sensor resistance is more than 156 kΩ (4.915 V) for 0.5 seconds or more (1 trip detection logic).
Open in No. 2 ATF temperature sensor circuit
No. 2 ATF temperature sensor (No. 1 transmission wire)
ECM

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 25 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM stores a DTC, and the ATF temperature warning light blinks or a message is displayed in the combination meter.


  • HINT:
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.
The ATF temperature can be checked on the intelligent tester display.

WIRING DIAGRAM

Refer to DTC P0712 ().


INSPECTION PROCEDURE

DATA LIST
  • HINT:
  • Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
  • NOTICE:
  • In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

Warm up the engine.

Turn the engine switch off.

Connect the intelligent tester to the DLC3.

Turn the engine switch on (IG).

Turn the intelligent tester on.

Enter the following menus: Powertrain / Engine and ECT / Data List.

According to the display on the intelligent tester, read the Data List.

Engine and ECT
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
A/T Oil Temperature 2No. 2 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)
After stall test: Approximately 80°C (176°F)
Equal to ambient temperature while engine is cold
If the value is -40°C (-40°F) or 150°C (302°F), the No. 2 ATF temperature sensor circuit is open or shorted.
  • HINT:
When DTC P2742 is output and the intelligent tester output is 150°C (302°F) or more, there is a short circuit.
When DTC P2743 is output and the intelligent tester output is -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO2 and the body ground.
Temperature DisplayedMalfunction
-40°C (-40°F)Open circuit
150°C (302°F) or moreShort circuit
1.INSPECT NO. 1 TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR)
Dtc P2742  Transmission Fluid Temperature Sensor B Circuit Low Input. AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the No. 1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    2 (OT2-) - 10 (OT2+)Always25 Ω to 156 kΩ
    2 (OT2-) - Body groundAlways10 kΩ or higher
    10 (OT2+) - Body groundAlways10 kΩ or higher
  • HINT:
  • If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
  • Standard Resistance:
  • ATF temperatureSpecified Condition
    10°C (50°F)5 to 8 kΩ
    25°C (77°F)2.5 to 4.5 kΩ
    110°C (230°F)0.22 to 0.28 kΩ
Text in Illustration
*aComponent without harness connected
(No. 1 Transmission Wire)
NG
REPAIR OR REPLACE NO. 2 ATF TEMPERATURE SENSOR (NO. 1 TRANSMISSION WIRE) ()
OK
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
Dtc P2742  Transmission Fluid Temperature Sensor B Circuit Low Input. AB60F AUTOMATIC TRANSMISSION / TRANSAXLE. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the ECM connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    C45-99 (THO2) - C45-98 (ETHA)Always25 Ω to 156 kΩ
    C45-99 (THO2) - Body groundAlways10 kΩ or higher
    C45-98 (ETHA) - Body groundAlways10 kΩ or higher
Text in Illustration
*aFront view of wire harness connector
(to ECM)
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE ECM ()