Starter Cut Relay - On-Vehicle Inspection
Using an ohmmeter, measure the resistance between each terminal.
- Standard resistance:
Tester Connection Specified Condition 3-5 10 MΩ or higher 3-5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
If the result is not as specified, replace the relay.