Lexus IS250 IS220d GSE20 ALE20 - A960E AUTOMATIC TRANSMISSION
SHIFT SOLENOID VALVE - INSPECTION
1. INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)1 - 2 5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SL1.
2. INSPECT SHIFT SOLENOID VALVE S1 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)Solenoid Connector (S1) - Solenoid Body (S1) 11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve S1.
3. INSPECT SHIFT SOLENOID VALVE S2 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)Solenoid Connector (S2) - Solenoid Body (S2) 11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating noise.
If the resistance is not within the specified range, replace the shift solenoid valve S2.
4. INSPECT SHIFT SOLENOID VALVE S3 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)Solenoid Connector (S3) - Solenoid Body (S3) 11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve S3.
5. INSPECT SHIFT SOLENOID VALVE S4 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)Solenoid Connector (S4) - Solenoid Body (S4) 11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve S4.
6. INSPECT SHIFT SOLENOID VALVE SL2 |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)1 - 2 5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SL2.
7. INSPECT SHIFT SOLENOID VALVE SR |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)Solenoid Connector (SR) - Solenoid Body (SR) 11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SR.
8. INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)1 - 2 5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SLT.
9. INSPECT SHIFT SOLENOID VALVE SLU |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Specified Condition
20°C (68°F)1 - 2 5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
If the resistance is not within the specified range, replace the shift solenoid valve SLU.