Lexus IS250 IS220d GSE20 ALE20 - AIR CONDITIONING

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK REFRIGERANT

CHECK WIRE HARNESS (PRESSURE SENSOR - A/C AMPLIFIER)

INSPECT PRESSURE SENSOR

DTC B1423/23 Pressure Switch Circuit

DESCRIPTION

This DTC is output when refrigerant pressure is extremely low (0.19 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.14 MPa (32.0 kgf/cm2, 455 psi) or more). The pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the A/C amplifier. The A/C amplifier converts this signal to pressure according to the sensor characteristics to control the compressor.


  • HINT:
  • Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be output if there is no refrigerant in the system.
DTC No.DTC Detection ConditionTrouble Area
B1423/23 Open or short in pressure switch circuit
Pressure sensor
Harness and connector between pressure sensor and A/C amplifier
Refrigerant pipe line
A/C amplifier

WIRING DIAGRAM

Dtc B1423/23  Pressure Switch Circuit. AIR CONDITIONING. Lexus IS250 IS220d GSE20 ALE20

INSPECTION PROCEDURE

1.CHECK REFRIGERANT
Dtc B1423/23  Pressure Switch Circuit. AIR CONDITIONING. Lexus IS250 IS220d GSE20 ALE20

Check the sight glass of the cooler unit refrigerant liquid pipe.


Prepare the vehicle according to the chart below.

ItemCondition
Vehicle DoorsFully open
Temperature SettingMAX COLD
Blower SpeedHI
A/CON

Compare the sight glass to the following chart.

ItemSymptomAmount of RefrigerantCorrective Actions
1 Bubbles visible Insufficient*
Check for gas leakage and repair if necessary
Add refrigerant until bubbles disappear
2 No bubbles visible Empty, insufficient, or excessive Refer to 3 and 4
3 No temperature difference between compressor inlet and outlet Empty or nearly empty
Check for gas leakage with gas leak detector and repair if necessary
Evacuate A/C system and recharge with proper amount of refrigerant
4 Considerable temperature difference between compressor inlet and outlet Proper or excessive Refer to 5 and 6
5 Immediately after air conditioning is turned OFF, refrigerant clears Excessive
Recover refrigerant
Evacuate A/C system and recharge with proper amount of refrigerant
6 Immediately after air conditioning is turned OFF, refrigerant foams and then becomes clear Proper-

*: Bubbles in the sight glass with the vehicle interior temperature above 35°C (95°F) can be considered normal if cooling is sufficient.


NG
CHARGE REFRIGERANT
OK
2.CHECK WIRE HARNESS (PRESSURE SENSOR - A/C AMPLIFIER)
Dtc B1423/23  Pressure Switch Circuit. AIR CONDITIONING. Lexus IS250 IS220d GSE20 ALE20

Disconnect the pressure sensor connector.

Disconnect the A/C amplifier connector.

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester ConnectionConditionSpecified Condition
    B7-2 (PR) - J58-13 (PRE)AlwaysBelow 1 Ω
    B7-3 (+) - J58-26 (S5-2)AlwaysBelow 1 Ω
    B7-1 (-) - J58-38 (SG-2)AlwaysBelow 1 Ω
    J58-13 (PRE) - Body groundAlways10 kΩ or higher
    J58-26 (S5-2) - Body groundAlways10 kΩ or higher
    J58-38 (SG-2) - Body groundAlways10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
3.INSPECT PRESSURE SENSOR

Install the manifold gauge set .

Dtc B1423/23  Pressure Switch Circuit. AIR CONDITIONING. Lexus IS250 IS220d GSE20 ALE20

Connect the three 1.5 V dry cell batterie's positive (+) lead to terminal 3 and the negative (-) lead to terminal 1. Then connect the voltmeter's positive (+) lead to terminal 2 and the negative (-) lead to terminal 1. Measure the voltage.

  • OK:
  • The voltage changes according to refrigerant pressure, as shown in the graph.
  • Result:
  • ResultProceed to
    NGA
    OK (When troubleshooting according to the DTC)B
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)C
B
REPLACE AIR CONDITIONING AMPLIFIER
C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A
REPLACE PRESSURE SENSOR