DTC No. | DTC Detection Condition | Trouble Area |
012 |
The surface sensor or control overheating sensor detects a temperature of 125°C (257°F) or more. |
Surface sensor (combustion heater assembly)
Control overheating sensor (combustion heater assembly)
Engine coolant circuit (for leaks, engine coolant quality, thermostat, water pump assembly)
|
014 |
When the engine coolant temperature is 80°C (176°F) and the combustion heater assembly is operating, the difference in temperatures detected by the surface sensor and control overheating sensor is 25°C (77°F) or more. |
Surface sensor (combustion heater assembly)
Control overheating sensor (combustion heater assembly)
Engine coolant circuit (for leaks, engine coolant quality, thermostat, water pump assembly)
|
017 |
When neither DTC 012 nor 014 is detected, the control overheating sensor or surface sensor detects a temperature of 130°C (266°F). |
Control overheating sensor (combustion heater assembly)
Surface sensor (combustion heater assembly)
Engine coolant circuit (for leaks, engine coolant quality, thermostat, water pump assembly)
|