Lexus IS250 IS220d GSE20 ALE20 - CAN COMMUNICATION

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK CAN BUS LINE (MAIN BUS LINE FOR OPEN, BUS LINES FOR SHORT CIRCUIT)

CHECK CAN BUS LINE (SHORT TO B+ IN CAN BUS LINE)

CHECK CAN BUS LINE (SHORT TO GND IN CAN BUS LINE)

2AD-FHV CAN COMMUNICATION SYSTEM (for LHD) - CAN Bus Line

DESCRIPTION

When any DTC for the CAN communication system is output, first measure the resistance between the terminals of the DLC3 to specify the trouble area. Then check that there is no short in the CAN main bus line, between the CAN bus lines, to B+, or to GND.


WIRING DIAGRAM

2Ad-Fhv Can Communication System (For Lhd) - Can Bus Line. CAN COMMUNICATION. Lexus IS250 IS220d GSE20 ALE20

INSPECTION PROCEDURE

1.CHECK CAN BUS LINE (MAIN BUS LINE FOR OPEN, BUS LINES FOR SHORT CIRCUIT)
2Ad-Fhv Can Communication System (For Lhd) - Can Bus Line. CAN COMMUNICATION. Lexus IS250 IS220d GSE20 ALE20

Turn the engine switch off.

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester ConnectionConditionSpecified Value
    J21-6 (CANH) - J21-14 (CANL)Engine switch off54 to 69 Ω
  • Result:
  • ResultProceed toSee Procedure
    OKA-
    69 Ω or higherB
    Below 54 ΩC
B
OPEN IN CAN MAIN BUS LINE
C
SHORT IN CAN BUS LINES
A
2.CHECK CAN BUS LINE (SHORT TO B+ IN CAN BUS LINE)
2Ad-Fhv Can Communication System (For Lhd) - Can Bus Line. CAN COMMUNICATION. Lexus IS250 IS220d GSE20 ALE20

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester ConnectionConditionSpecified Value
    J21-6 (CANH) - J21-16 (BAT)Engine switch off1 MΩ or higher
    J21-14 (CANL) - J21-16 (BAT)Engine switch off1 MΩ or higher
  • Result:
  • ResultSee Procedure
    OKGo to step 3
    NG
NG
SHORT TO B+ IN CAN BUS LINE
OK
3.CHECK CAN BUS LINE (SHORT TO GND IN CAN BUS LINE)
2Ad-Fhv Can Communication System (For Lhd) - Can Bus Line. CAN COMMUNICATION. Lexus IS250 IS220d GSE20 ALE20

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester ConnectionConditionSpecified Value
    J21-4 (CG) - J21-6 (CANH)Engine switch off1 kΩ or higher
    J21-4 (CG) - J21-14 (CANL)Engine switch off1 kΩ or higher
  • Result:
  • ResultSee Procedure
    OK
    NG
NG
SHORT TO GND IN CAN BUS LINE
OK
GO TO "HOW TO PROCEED WITH TROUBLESHOOTING"