Power Door Lock Control System - Door Opening Relay Power Source Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK WIRE HARNESS (DOUBLE DOOR LOCK ECU - BATTERY AND BODY GROUND)
POWER DOOR LOCK CONTROL SYSTEM - Door Opening Relay Power Source Circuit
DESCRIPTION
This circuit supplies power to operate the double door lock ECU (door opening relay).
WIRING DIAGRAM

INSPECTION PROCEDURE
1.CHECK WIRE HARNESS (DOUBLE DOOR LOCK ECU - BATTERY AND BODY GROUND) |
Disconnect the double door lock ECU (door opening relay) connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection (Symbols) | Condition | Specified Condition |
P34-14 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection (Symbols) | Condition | Specified Condition |
P34-1 (+B) - Body ground | Always | 10 to 14 V |
P34-7 (CPUB) - Body ground | Always | 10 to 14 V |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK | |
| |
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|