Lexus IS250 IS220d GSE20 ALE20 - DOOR LOCK

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT ENTRY LOCK SWITCH

CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ENTRY LOCK SWITCH)

CHECK HARNESS AND CONNECTOR (ELECTRICAL KEY OSCILLATOR - ENTRY LOCK SWITCH)

CHECK AND REPLACE ELECTRICAL KEY OSCILLATOR

ENTRY AND START SYSTEM - Entry Lock Switch Circuit

DESCRIPTION

The entry lock switches (trigger switch) are built into the outside handles of the LH/RH door. The certification ECU detects the conditions of the each lock switch.


WIRING DIAGRAM

Entry And Start System - Entry Lock Switch Circuit. DOOR LOCK. Lexus IS250 IS220d GSE20 ALE20

INSPECTION PROCEDURE

1.INSPECT ENTRY LOCK SWITCH
Entry And Start System - Entry Lock Switch Circuit. DOOR LOCK. Lexus IS250 IS220d GSE20 ALE20

Remove the outside handle.

Disconnect the connectors.

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester Connection (Symbols)ConditionSpecified Condition
    o1-1 (TRG-) - o1-3 (TRG+)Lock switch not pushed10 kΩ or higher
    Lock switch pushedBelow 1 Ω
    n1-1 (TRG-) - n1-3 (TRG+)Lock switch not pushed10 kΩ or higher
    Lock switch pushedBelow 1 Ω
NG
REPLACE OUTSIDE HANDLE ASSEMBLY
OK
2.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ENTRY LOCK SWITCH)
Entry And Start System - Entry Lock Switch Circuit. DOOR LOCK. Lexus IS250 IS220d GSE20 ALE20

Disconnect the P33 ECU connector.

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester Connection (Symbols)ConditionSpecified Condition
    P33-3 (TSW1) - o1-3 (TRG+)AlwaysBelow 1 Ω
    P33-4 (TSW1) - n1-3 (TRG+)AlwaysBelow 1 Ω
    P33-3 (TSW1) - Body groundAlways10 kΩ or higher
    P33-4 (TSW1) - Body groundAlways10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
3.CHECK HARNESS AND CONNECTOR (ELECTRICAL KEY OSCILLATOR - ENTRY LOCK SWITCH)
Entry And Start System - Entry Lock Switch Circuit. DOOR LOCK. Lexus IS250 IS220d GSE20 ALE20

Disconnect the door oscillator connector.

Measure the resistance according to the value(s) in the table below.

  • Standard resistance:
  • Tester Connection
    (Symbols)
    ConditionSpecified condition
    o2-9 (TRG-) - o1-1 (TRG-)AlwaysBelow 1 Ω
    n2-9 (TRG-) - n1-1 (TRG-)AlwaysBelow 1 Ω
    o2-9 (TRG-) - Body groundAlways10 kΩ or higher
    n2-9 (TRG-) - Body groundAlways10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4.CHECK AND REPLACE ELECTRICAL KEY OSCILLATOR

Replace the electrical key oscillator.

Check that the entry LOCK / UNLOCK function operates normally.

  • OK:
  • Entry LOCK / UNLOCK function operates normally.
NG
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
OK
END (ELECTRICAL KEY OSCILLATOR IS DEFECTIVE)