Lexus IS250 IS220d GSE20 ALE20 2AD-FHV CHARGING
BATTERY CURRENT SENSOR - ON-VEHICLE INSPECTION
1. INSPECT BATTERY CURRENT SENSOR |
Resistance inspection

Using an ohmmeter, measure the resistance between terminals.
- Resistance:
Terminals: Positive (+) tester probe - Negative (-) tester probe Resistance 3 (VC5) - 2 (E2) 3 to 6 kΩ 2 (E2) - 3 (VC5) 0.7 to 8 kΩ 3 (VC5) - 1 (IB) 0.2 to 0.3 kΩ 1 (IB) - 3 (VC5) 0.2 to 3 kΩ 2 (E2) - 1 (IB) 1.5 to 8 kΩ 1 (IB) - 2 (E2) 3 to 6 kΩ
If the results are not as specified, replace the battery current sensor assembly.
LEXUS IS250, IS220d / GSE20 ALE20