Air Switching Valve (For Bank 2) Removal
REMOVE V-BANK COVER SUB-ASSEMBLY
REMOVE AIR CLEANER CAP AND HOSE
DISCONNECT NO. 3 PCV HOSE
DISCONNECT NO. 1 AIR INJECTION SYSTEM HOSE
REMOVE AIR SWITCHING VALVE ASSEMBLY
Air Switching Valve (For Bank 2) -- Removal |
1. REMOVE V-BANK COVER SUB-ASSEMBLY |
Raise the front of the V-bank cover to detach the 3 pins. Then remove the 2 V-bank cover hooks from the bracket, and remove the V-bank cover.
Text in Illustration*1
| Grommet
|
*2
| Pin
|
*3
| Hook
|
*4
| Bracket
|
2. REMOVE AIR CLEANER CAP AND HOSE |
Disconnect the No. 2 PCV hose and No. 1 air hose.
Disconnect the mass air flow meter connector and detach the clamp.
Detach the 4 clamps.
Loosen the hose clamp and remove the air cleaner cap and hose.
3. DISCONNECT NO. 3 PCV HOSE |
Disconnect the No. 3 PCV hose.
4. DISCONNECT NO. 1 AIR INJECTION SYSTEM HOSE |
Disconnect the No. 1 air injection system hose.
5. REMOVE AIR SWITCHING VALVE ASSEMBLY |
Detach the wire harness clamp and disconnect the air switching valve connector.
Remove the 2 bolts.
Remove the 3 bolts, air switching valve and gasket.
- NOTICE:
- Be careful not to damage the surfaces that contact the gasket.