Valve Body Assembly Inspection
Drivetrain. Land Cruiser. Urj200, 202 Grj200 Vdj200
INSPECT SHIFT SOLENOID VALVE SR
INSPECT SHIFT SOLENOID VALVE SLU
INSPECT SHIFT SOLENOID VALVE SL2
INSPECT SHIFT SOLENOID VALVE SLT
INSPECT SHIFT SOLENOID VALVE SL1
INSPECT SHIFT SOLENOID VALVE S1
INSPECT SHIFT SOLENOID VALVE S2
Valve Body Assembly -- Inspection |
1. INSPECT SHIFT SOLENOID VALVE SR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Solenoid Connector (SR) - Solenoid Body (SR)
| 20°C (68°F)
| 11 to 15 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) → Shift solenoid valve SR connector
- Battery negative (-) → Shift solenoid valve SR body
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
2. INSPECT SHIFT SOLENOID VALVE SLU |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Terminal 1 of shift solenoid valve SLU - terminal 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
3. INSPECT SHIFT SOLENOID VALVE SL2 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Terminal 1 of shift solenoid valve SL2 - terminal 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
4. INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Terminal 1 of shift solenoid valve SLT - terminal 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
5. INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Terminal 1 of shift solenoid valve SL1 - terminal 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
6. INSPECT SHIFT SOLENOID VALVE S1 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Solenoid Connector (S1) - Solenoid Body (S1)
| 20°C (68°F)
| 11 to 15 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) → Shift solenoid valve S1 connector
- Battery negative (-) → Shift solenoid valve S1 body
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.
7. INSPECT SHIFT SOLENOID VALVE S2 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Solenoid Connector (S2) - Solenoid Body (S2)
| 20°C (68°F)
| 11 to 15 Ω
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) → Shift solenoid valve S2 connector
- Battery negative (-) → Shift solenoid valve S2 body
| Valve moves and makes an operating noise
|
If the result is not as specified, replace the solenoid valve.