Valve Body Assembly Inspection
Drivetrain. Land Cruiser. Urj200, 202 Grj200 Vdj200
INSPECT SHIFT SOLENOID VALVE SL1
INSPECT SHIFT SOLENOID VALVE SL2
INSPECT SHIFT SOLENOID VALVE SL3
INSPECT SHIFT SOLENOID VALVE SL4
INSPECT SHIFT SOLENOID VALVE SL5
INSPECT SHIFT SOLENOID VALVE SLU
INSPECT SHIFT SOLENOID VALVE SLT
INSPECT SHIFT SOLENOID VALVE SC1
INSPECT SHIFT SOLENOID VALVE SC2
Valve Body Assembly -- Inspection |
1. INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Text in Illustration*a
| Component without harness connected (Shift Solenoid Valve SL1)
|
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SL1 connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL1.
2. INSPECT SHIFT SOLENOID VALVE SL2 |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
3. INSPECT SHIFT SOLENOID VALVE SL3 |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
4. INSPECT SHIFT SOLENOID VALVE SL4 |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
5. INSPECT SHIFT SOLENOID VALVE SL5 |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
6. INSPECT SHIFT SOLENOID VALVE SLU |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
7. INSPECT SHIFT SOLENOID VALVE SLT |
- HINT:
- Refer to the procedures for the shift solenoid valve SL1.
8. INSPECT SHIFT SOLENOID VALVE SC1 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Shift solenoid valve SC1 connector terminal - Shift solenoid valve SC1 body
| 15 to 25°C (59 to 77°F)
| 11 to 15 Ω
|
Text in Illustration*a
| Component without harness connected (Shift Solenoid Valve SC1)
|
Connect the positive (+) lead to the terminal of the shift solenoid valve SC1 connector, and the negative (-) lead to the shift solenoid valve SC1 body.
- OK:
- The solenoid makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SC1.
9. INSPECT SHIFT SOLENOID VALVE SC2 |
- HINT:
- Refer to the procedures for the shift solenoid valve SC1.