Dtc B1429/29 Rear Air Foot Duct Sensor Circuit On Front Passenger Side
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (FOOT DUCT SENSOR [REAR P])
INSPECT COOLER THERMISTOR (DUCT SENSOR)
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR [DUCT SENSOR])
DTC B1429/29 Rear Air Foot Duct Sensor Circuit on Front Passenger Side |
DESCRIPTION
- 1: for LHD
- 2: for RHD
The cooler thermistor (duct sensor RH*1 or LH*2) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.DTC Code
| DTC Detection Condition
| Trouble Area
|
B1429/29
| An open or short in the air duct temperature sensor RH*1 or LH*2 circuit.
| - Cooler thermistor (duct sensor RH)*1
- Cooler thermistor (duct sensor LH)*2
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (FOOT DUCT SENSOR [REAR P]) |
- *1: for LHD
- *2: for RHD
Use the Data List to check if the cooler thermistor (duct temperature sensor RH*1 or LH*2) is functioning properly (Click here).
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Foot Duct Sensor (Rear P)
| Cooler thermistor (duct sensor RH*1 or LH*2) / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F)
| Actual cooler thermistor (duct sensor RH*1 or LH*2) displayed
| Cooler thermistor (duct sensor RH*1 or LH*2) system malfunction:
- Open in the circuit: -12.7°C (9.14°F)
- Short in the circuit: 76.55°C (169.79°F)
|
- OK:
- The display is as specified in the normal condition.
ResultResult
| Proceed to
|
OK (When troubleshooting according to the DTC)
| A
|
OK (When troubleshooting according to Problem Symptoms Table)
| B
|
NG
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here) |
|
|
| |
|
A |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|
2.INSPECT COOLER THERMISTOR (DUCT SENSOR) |
- *1: for LHD
- *2: for RHD
Remove the cooler thermistor (duct sensor RH*1 or LH*2) (Click here).
Inspect the the cooler thermistor (duct sensor RH*1 or LH*2) (Click here).
| REPLACE COOLER THERMISTOR (DUCT SENSOR) (Click here) |
|
|
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR [DUCT SENSOR]) |
Disconnect the E35 air conditioning amplifier assembly connector.
for LHD:
Disconnect the L12 cooler thermistor (duct sensor RH) connector.
for RHD:
Disconnect the K21 cooler thermistor (duct sensor LH) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
- for LHD::
Tester Connection
| Condition
| Specified Condition
|
E35-17 (RHTR) - L12-1
| Always
| Below 1 Ω
|
E35-31 (SGND) - L12-2 (-)
| Always
| Below 1 Ω
|
L12-1 - L12-2
| Always
| 10 kΩ or higher
|
E35-17 (RHTR) or L12-1 - Body ground
| Always
| 10 kΩ or higher
|
E35-31 (SGND) or L12-2 - Body ground
| Always
| 10 kΩ or higher
|
- for RHD::
Tester Connection
| Condition
| Specified Condition
|
E35-18 (RHTL) - K21-1
| Always
| Below 1 Ω
|
E35-31 (SGND) - K21-2
| Always
| Below 1 Ω
|
K21-1 - K21-2
| Always
| 10 kΩ or higher
|
E35-18 (RHTL) or K21-1 - Body ground
| Always
| 10 kΩ or higher
|
E35-31 (SGND) or K21-2 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|