Dtc B1429/29 Rear Air Foot Duct Sensor Circuit On Front Passenger Side

Vehicle Interior. Land Cruiser. Urj200, 202 Grj200 Vdj200
Heating Air Conditioning. Land Cruiser. Urj200, 202 Grj200 Vdj200

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR)

CHECK AIR DUCT TEMPERATURE SENSOR

CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR)

DTC B1429/29 Rear Air Foot Duct Sensor Circuit on Front Passenger Side


DESCRIPTION

The air duct temperature sensor RH*1 or LH*2 (for front passenger side) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.

DTC Code
DTC Detection Condition
Trouble Area
B1429/29
An open or short in the air duct temperature sensor RH*1 or LH*2 circuit.
  1. Air duct temperature sensor RH*1
  2. Air duct temperature sensor LH*2
  3. Harness or connector (air duct temperature sensor RH)*1
  4. Harness or connector (air duct temperature sensor LH)*2
  5. Air conditioning amplifier assembly
HINT:
*1: for LHD
*2: for RHD

WIRING DIAGRAM


Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  B1429/29  Rear Air Foot Duct Sensor Circuit On Front Passenger Side


Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  B1429/29  Rear Air Foot Duct Sensor Circuit On Front Passenger Side


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR)
  1. Use the Data List to check if the air duct temperature sensor RH*1 or LH*2 (for front passenger side) is functioning properly.

    Air Conditioner
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Foot Duct Sensor (Rear P)
    Min.: -12.7°C (9.14°F)
    Max.: 76.55°C (169.79°F)
    Actual air duct temperature sensor (for passenger side) displayed
    Open in the circuit: -12.7°C (9.14°F)
    Short in the circuit: 76.55°C (169.79°F)
    HINT:
    *1: for LHD
    *2: for RHD
    OK:
    The display is as specified in the normal condition.


NG
Go to step 2
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

2.CHECK AIR DUCT TEMPERATURE SENSOR
Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  B1429/29  Rear Air Foot Duct Sensor Circuit On Front Passenger Side
  1. for LHD

    1. Remove the air duct temperature sensor RH (Click here).

  1. for RHD

    1. Remove the air duct temperature sensor LH (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (+) - 2 (-)
    at 10°C (50°F)
    9.4 to 10.5 kΩ
    at 15°C (59°F)
    7.5 to 8.3 kΩ
    at 20°C (68°F)
    6.0 to 6.5 kΩ
    at 25°C (77°F)
    4.5 to 5.2 kΩ
    at 30°C (86°F)
    3.8 to 4.2 kΩ
    at 35°C (95°F)
    3.1 to 3.4 kΩ
    at 40°C (104°F)
    2.5 to 2.8 kΩ
    at 45°C (113°F)
    2.0 to 2.3 kΩ
    at 50°C (122°F)
    1.6 to 2.0 kΩ
    at 55°C (131°F)
    1.3 to 1.6 kΩ
    at 60°C (140°F)
    1.1 to 1.4 kΩ
    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
    2. When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
    HINT:
    As the temperature increases, the resistance decreases (see the graph).
    If the resistance value is not as specified, replace the sensor.
    Result
    Result
    Proceed to
    OK
    A
    NG (for LHD)
    B
    NG (for RHD)
    C


B
REPLACE AIR DUCT TEMPERATURE SENSOR RH (Click here)

C
REPLACE AIR DUCT TEMPERATURE SENSOR LH (Click here)
A


3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR)
Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  B1429/29  Rear Air Foot Duct Sensor Circuit On Front Passenger Side
  1. for LHD

    1. Disconnect the L12 sensor connector.

    2. Disconnect the E35 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      E35-26 (TR4) - L12-1 (+)
      Always
      Below 1 Ω
      E35-12 (SG-9) - L12-2 (-)
      E35-26 (TR4) - Body ground
      Always
      10 kΩ or higher
      E35-12 (SG-9) - Body ground


    Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  B1429/29  Rear Air Foot Duct Sensor Circuit On Front Passenger Side
  1. for RHD

    1. Disconnect the K21 sensor connector.

    2. Disconnect the E35 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      E35-25 (TR3) - K21-1 (+)
      Always
      Below 1 Ω
      E35-34 (SGND) - K21-2 (-)
      E35-25 (TR3) - Body ground
      Always
      10 kΩ or higher
      E35-34 (SGND) - Body ground


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK