Dtc B1467/67 Rear Air Foot Duct Sensor Circuit On Driver Side
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR)
CHECK AIR DUCT TEMPERATURE SENSOR
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR)
DTC B1467/67 Rear Air Foot Duct Sensor Circuit on Driver Side |
DESCRIPTION
The air duct temperature sensor LH*1 or RH*2 (for driver side) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.DTC Code
| DTC Detection Condition
| Trouble Area
|
B1467/67
| An open or short in the air duct temperature sensor LH*1 or RH*2 circuit.
| - Air duct temperature sensor LH*1
- Air duct temperature sensor RH*2
- Harness or connector (air duct temperature sensor LH)*1
- Harness or connector (air duct temperature sensor RH)*2
- Air conditioning amplifier assembly
|
- HINT:
- *1: for LHD
- *2: for RHD
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR) |
Use the Data List to check if the air duct temperature sensor LH*1 or RH*2 (for driver side) is functioning properly.
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Foot Duct Sensor (Rear D)
| Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F)
| Actual air duct temperature sensor (for driver side) displayed
| Open in the circuit: -12.7°C (9.14°F) Short in the circuit: 76.55°C (169.79°F)
|
- HINT:
- *1: for LHD
- *2: for RHD
- OK:
- The display is as specified in the normal condition.
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|
2.CHECK AIR DUCT TEMPERATURE SENSOR |
for LHD
Remove the air duct temperature sensor LH (Click here).
for RHD
Remove the air duct temperature sensor RH (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 (+) - 2 (-)
| at 10°C (50°F)
| 9.4 to 10.5 kΩ
|
at 15°C (59°F)
| 7.5 to 8.3 kΩ
|
at 20°C (68°F)
| 6.0 to 6.5 kΩ
|
at 25°C (77°F)
| 4.5 to 5.2 kΩ
|
at 30°C (86°F)
| 3.8 to 4.2 kΩ
|
at 35°C (95°F)
| 3.1 to 3.4 kΩ
|
at 40°C (104°F)
| 2.5 to 2.8 kΩ
|
at 45°C (113°F)
| 2.0 to 2.3 kΩ
|
at 50°C (122°F)
| 1.6 to 2.0 kΩ
|
at 55°C (131°F)
| 1.3 to 1.6 kΩ
|
at 60°C (140°F)
| 1.1 to 1.4 kΩ
|
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
- If the resistance value is not as specified, replace the sensor.
ResultResult
| Proceed to
|
OK
| A
|
NG (for LHD)
| B
|
NG (for RHD)
| C
|
| REPLACE AIR DUCT TEMPERATURE SENSOR LH (Click here) |
|
|
| REPLACE AIR DUCT TEMPERATURE SENSOR RH (Click here) |
|
|
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR) |
for LHD
Disconnect the K21 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E35-25 (TR3) - K21-1 (+)
| Always
| Below 1 Ω
|
E35-34 (SGND) - K21-2 (-)
|
E35-25 (TR3) - Body ground
| Always
| 10 kΩ or higher
|
E35-34 (SGND) - Body ground
|
for RHD
Disconnect the L12 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E35-26 (TR4) - L12-1 (+)
| Always
| Below 1 Ω
|
E35-12 (SG-9) - L12-2 (-)
|
E35-26 (TR4) - Body ground
| Always
| 10 kΩ or higher
|
E35-12 (SG-9) - Body ground
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|