Air Conditioning System (For Manual Air Conditioning System) Blower Motor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BATTERY AND BODY GROUND)
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY
AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) - Blower Motor Circuit |
DESCRIPTION
The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. The blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR) |
Select the Active Test, use the GTS to generate a control command, and then check that the blower with fan motor sub-assembly operates (Click here).
Air ConditionerTester Display
| Test Part
| Control Range
| Diagnostic Note
|
Blower Motor
| Blower with fan motor sub-assembly
| Min.: 0, Max.: 31
| -
|
- OK:
- Blower with fan motor sub-assembly is operated normally using GTS.
OK |
|
|
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here) |
|
2.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BATTERY AND BODY GROUND) |
Disconnect the blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A29-1 (GND) - Body ground
| Always
| Below 1 Ω
|
Measure the voltage according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A29-3 (+B) - Body ground
| Always
| 11 to 14 V
|
Text in Illustration*a
| Front view of wire harness connector (to Blower with Fan Motor Sub-assembly)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the A29 blower with fan motor sub-assembly connector.
Disconnect the E81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Switch Condition
| Specified Condition
|
A29-2 (SI) - E81-22 (BLW)
| Always
| Below 1 Ω
|
A29-2 (SI) or E81-22 (BLW) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
Using an oscilloscope, check the waveform
Measurement ConditionItem
| Content
|
Terminal No. (Symbol)
| A29-2 (SI) - Body ground
|
Tool Setting
| 1 V/DIV., 500 μs/DIV.
|
Condition
| - Ignition switch ON
- Blower switch LO
|
- OK:
- Waveform is as shown in the illustration.
Text in Illustration*a
| Component with harness connected (Blower with Fan Motor Sub-assembly)
|
- HINT:
- Waveform varies with the blower level.
OK |
|
|
|
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY (Click here) |
|
5.CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY |
Replace the blower with fan motor sub-assembly with a new or known good one (Click here).
Check that the air conditioning system is operated normally.
- OK:
- Air conditioning system is operated normally.
| REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|
|
OK |
|
|
|
END (BLOWER WITH FAN MOTOR SUB-ASSEMBLY WAS DEFECTIVE) |
|