Air Conditioning System (For Automatic Air Conditioning System) Data List / Active Test

Vehicle Interior. Land Cruiser. Urj200, 202 Grj200 Vdj200
Heating Air Conditioning. Land Cruiser. Urj200, 202 Grj200 Vdj200
  1. DATA LIST

  1. ACTIVE TEST

Air Conditioning System (For Automatic Air Conditioning System) -- Data List / Active Test


HINT:
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

DATA LIST
  1. Connect the GTS to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the GTS on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

  5. Enter the following menus: Powertrain / Engine and ECT / Data List.

  6. According to the display on the GTS, read the Data List.

    Air Conditioner
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Cooler thermistor (room temperature sensor) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F)
    Actual room temperature for front seat displayed
    Cooler thermistor (room temperature sensor) system malfunction:
    1. Open in the circuit: -6.5°C (20.3°F)
    2. Short in the circuit: 57.25°C (135.05°F)
    Ambient Temp Sensor
    Cooler thermistor (ambient temperature sensor) / Min.: -23.3°C (-9.94°F), Max.: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    Thermistor assembly (ambient temperature sensor) system malfunction:
    1. Open in the circuit: -23.3°C (-9.94°F)
    2. Short in the circuit: 65.95°C (150.71°F)
    Adjusted Ambient Temp
    Adjusted ambient temperature /Min.: -30.8°C (-23.44°F), Max.: 50.8°C (123.44°F)
    Adjusted ambient temperature displayed
    Air conditioning amplifier assembly
    Evaporator Fin Thermistor
    No. 1 cooler thermistor (evaporator temperature sensor) / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
    1. Open in the circuit: -29.7°C (-21.46°F)
    2. Short in the circuit: 59.55°C (139.19°F)
    Engine Coolant Temp
    Engine coolant temperature / Min.: 1.3°C (34.34°F), Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature displayed while engine warmed up
    1. SFI system malfunction
    2. CAN communication system malfunction
    Blower Motor Speed Level
    Blower with fan motor sub-assembly speed level / Min.: 0 level, Max.: 31 level
    Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases
    Displayed speed level increases in range between 0 and 31 as blower with fan motor subassembly speed increases
    Regulator Pressure Sensor
    Air conditioner pressure sensor / Min.: 0.4566 MPa, Max.: 3.2943 MPa
    Actual refrigerant pressure displayed
    1. Air conditioning system (leaks, blocked)
    2. Air conditioner pressure sensor system malfunction
    Room Temp Sensor (Rear)
    Cooler thermistor (No. 2 room temperature sensor) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F)
    Actual rear room temperature seat displayed
    Cooler thermistor (No. 2 room temperature sensor) system malfunction:
    1. Open in the circuit: -6.5°C (20.3°F)
    2. Short in the circuit: 57.25°C (135.05°F)
    Evap Temp Sensor (Rear)
    No. 2 air conditioning harness assembly (rear evaporator temperature sensor) / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F)
    Actual rear evaporator temperature displayed
    No. 2 air conditioning harness assembly (rear evaporator temperature sensor) system malfunction:
    1. Open in the circuit: -29.7°C (-21.46°F)
    2. Short in the circuit: 59.55°C (139.19°F)
    Blower Motor Level (Rear)
    Rear blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31
    Displayed speed level increases in range between 0 and 31 as rear blower with fan motor subassembly speed increases
    Rear blower with fan motor sub-assembly system malfunction
    Air Outlet Servo Pulse (R)
    Rear mode damper servo motor target pulse / Min.: 128, Max.:383
    1. FOOT: 135 (pulse)
    2. B/L: 170 (pulse)
    3. FACE: 211 (pulse)
    1. Displayed between 135 and 211 pulse
    2. Rear mode damper servo motor system malfunction
    Air Outlet Servo Actual Pulse(R)
    Rear mode damper servo motor actual pulse / Min.: 128, Max.:383
    1. FOOT: 135 (pulse)
    2. B/L: 170 (pulse)
    3. FACE: 211 (pulse)
    1. Displayed between 135 and 211 pulse
    2. Rear mode damper servo motor system malfunction
    Air Mix Servo Targ Pulse(R)
    Rear air mix damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 137 (pulse)
    2. MAX HOT: 182 (pulse)
    for RHD:
    1. MAX COLD: 181 (pulse)
    2. MAX HOT: 136 (pulse)
    1. Displayed between 137 and 182 pulse (for LHD)
    2. Displayed between 136 and 181 pulse (for RHD)
    3. Rear air mix damper servo motor LH*1 or RH*2 system malfunction
    Air Mix Servo Actual Pulse(R)
    Rear air mix damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 137 (pulse)
    2. MAX HOT: 182 (pulse)
    for RHD:
    1. MAX COLD: 181 (pulse)
    2. MAX HOT: 136 (pulse)
    1. Displayed between 137 and 182 pulse (for LHD)
    2. Displayed between 136 and 181 pulse (for RHD)
    3. Rear air mix damper servo motor LH*1 or RH*2 system malfunction
    Air Mix Servo Targ Pulse(D)
    Air mix damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 218 (pulse)
    2. MAX HOT: 136 (pulse)
    for RHD:
    1. MAX COLD: 136 (pulse)
    2. MAX HOT: 218 (pulse)
    1. Displayed between 136 and 218 pulse
    2. Air mix damper servo motor LH*1 or RH*2 system malfunction
    Air Mix Servo Actual Pulse(D)
    Air mix damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 218 (pulse)
    2. MAX HOT: 136 (pulse)
    for RHD:
    1. MAX COLD: 136 (pulse)
    2. MAX HOT: 218 (pulse)
    1. Displayed between 136 and 218 pulse
    2. Air mix damper servo motor LH*1 or RH*2 system malfunction
    Air Mix Servo Targ Pulse(P)
    Air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 136 (pulse)
    2. MAX HOT: 218 (pulse)
    for RHD:
    1. MAX COLD: 218 (pulse)
    2. MAX HOT: 136 (pulse)
    1. Displayed between 136 and 218 pulse
    2. Air mix damper servo motor RH*1 or LH*2 system malfunction
    Air Mix Servo Actual Pulse(P)
    Air mix damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 136 (pulse)
    2. MAX HOT: 218 (pulse)
    for RHD:
    1. MAX COLD: 218 (pulse)
    2. MAX HOT: 136 (pulse)
    1. Displayed between 136 and 218 pulse
    2. Air mix damper servo motor RH*1 or LH*2 system malfunction
    Air Outlet Servo Pulse (D)
    Mode damper servo motor LH*1 or RH*2 target pulse / Min.: 128, Max.:383
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 180 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    1. Displayed between 134 and 245 pulse
    2. Mode damper servo motor LH*1 or RH*2 system malfunction
    Air Outlet Servo Actu Pulse(D)
    Mode damper servo motor LH*1 or RH*2 actual pulse / Min.: 128, Max.:383
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 180 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    1. Displayed between 136 and 245 pulse
    2. Mode damper servo motor LH*1 or RH*2 system malfunction
    Air Outlet Servo Targ Pulse(P)
    Mode damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.:383
    for LHD:
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 180 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    for RHD:
    1. FACE1: 137 (pulse)
    2. FACE2: 145 (pulse)
    3. B/L1: 161 (pulse)
    4. B/L2: 173 (pulse)
    5. FOOT-O: 183 (pulse)
    6. FOOT-D: 202 (pulse)
    7. FOOT-R: 213 (pulse)
    8. FOOT-F: 213 (pulse)
    9. F/D: 263 (pulse)
    10. DEF: 248 (pulse)
    1. Displayed between 136 and 245 pulse (for LHD)
    2. Displayed between 137 and 248 pulse (for RHD)
    3. Mode damper servo motor RH*1 or LH*2 system malfunction
    Air Outlet Servo Actu Pulse(P)
    Mode damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.:383
    for LHD:
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 180 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    for RHD:
    1. FACE1: 137 (pulse)
    2. FACE2: 145 (pulse)
    3. B/L1: 161 (pulse)
    4. B/L2: 173 (pulse)
    5. FOOT-O: 183 (pulse)
    6. FOOT-D: 202 (pulse)
    7. FOOT-R: 213 (pulse)
    8. FOOT-F: 213 (pulse)
    9. F/D: 263 (pulse)
    10. DEF: 248 (pulse)
    1. Displayed between 136 and 245 pulse (for LHD)
    2. Displayed between 137 and 248 pulse (for RHD)
    3. Mode damper servo motor RH*1 or LH*2 system malfunction
    Air Inlet Damper Targ Pulse
    Mode damper servo motor (REC/FRS) target pulse / Min.: 128, Max.:383
    for LHD:
    1. RECIRCULATION: 165 (pulse)
    2. FRESH: 137 (pulse)
    for RHD:
    1. RECIRCULATION: 137 (pulse)
    2. FRESH: 165 (pulse)
    1. Displayed between 137 and 165 pulse
    2. Mode damper servo motor (REC/FRS) system malfunction
    Air Inlet Damper Actual Pulse
    Mode damper servo motor (REC/FRS) actual pulse / Min.: 128, Max.:383
    for LHD:
    1. RECIRCULATION: 165 (pulse)
    2. FRESH: 137 (pulse)
    for RHD:
    1. RECIRCULATION: 137 (pulse)
    2. FRESH: 165 (pulse)
    1. Displayed between 137 and 165 pulse
    2. Mode damper servo motor (REC/FRS) system malfunction
    Cool Air Bypass Pulse
    Cool air bypass damper servo motor target pulse / Min.: 128, Max.:383
    1. Shut: 134 (pulse)
    2. Open: 185 (pulse)
    1. Displayed between 134 and 185 pulse
    2. Cool air bypass damper servo motor) system malfunction
    Cool Air Bypass Actual Pulse
    Cool air bypass damper servo motor actual pulse / Min.: 128, Max.:383
    1. Shut: 134 (pulse)
    2. Open: 185 (pulse)
    1. Displayed between 134 and 185 pulse
    2. Cool air bypass damper servo motor) system malfunction
    Electric Heater Count
    Electric heater count /
    Min.: 0, Max.: 3
    Maximum possible operation of electric heater displayed
    PTC heater system malfunction
    Electric Heater Active Level
    Actual electric heater operation level
    Actual operation level of electric heater displayed
    PTC heater system malfunction
    Shift Set Temperature
    Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C
    Customized value displayed
    -
    Air Inlet Mode
    Air inlet mode / AUTO, MANUAL
    Customized value displayed
    -
    Compressor Mode
    Compressor mode / AUTO, MANUAL
    Customized value displayed
    -
    Add Foot Air in Face Mode
    Additional amount of air blow to the foot area / ON, OFF
    Customized value displayed
    -
    ECO MODE Cancel
    ECO mode cancel / ON. OFF
    Customized value displayed
    w/ ECO Mode Switch
    ECO Switch
    Integration control and panel assembly / OFF, ON
    ON: Integration control and panel assembly being turned and held at ECO position
    OFF: integration control and panel assembly not turned
    w/ ECO Mode Switch
    Refrigerant Shortage Check
    Refrigerant gas volume check / ON, OFF
    Customized value displayed
    -
    Fan speed increment control
    Blower with fan motor sub-assembly speed / Slow, Normal, ,Fast
    Customized value displayed
    -
    Foot/DEF Auto Moden
    Foot/DEF auto mode / ON, OFF
    Customized value displayed
    -
    Foot/DEF Automatic Blow Up Function
    Foot/DEF auto blower speed increase / ON, OFF
    Customized value displayed
    -
    Ambient Temperature Shift
    Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C
    Customized value displayed
    -
    Air Mix Servo Targ Pls(F&R D)
    Air mix damper servo motor (rear LH*1 or RH*2) target pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 141 (pulse)
    2. MAX HOT: 169 (pulse)
    for RHD:
    1. MAX COLD: 161 (pulse)
    2. MAX HOT: 133 (pulse)
    1. Displayed between 141 and 169 pulse (for LHD)
    2. Displayed between 133 and 161 pulse (for RHD)
    3. Air mix damper servo motor (rear LH*1 or RH*2) system malfunction
    A/M Servo Actual Pulse(F&R D)
    Air mix damper servo motor (rear LH*1 or RH*2) actual pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 141 (pulse)
    2. MAX HOT: 169 (pulse)
    for RHD:
    1. MAX COLD: 161 (pulse)
    2. MAX HOT: 133 (pulse)
    1. Displayed between 141 and 169 pulse (for LHD)
    2. Displayed between 133 and 161 pulse (for RHD)
    3. Air mix damper servo motor (rear LH*1 or RH*2) system malfunction
    Air Mix Servo Targ Pls(F&R P)
    Air mix damper servo motor (rear RH*1 or LH*2) target pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 161 (pulse)
    2. MAX HOT: 133 (pulse)
    for RHD:
    1. MAX COLD: 141 (pulse)
    2. MAX HOT: 169 (pulse)
    1. Displayed between 133 and 161 pulse (for LHD)
    2. Displayed between 141 and 169 pulse (for RHD)
    3. Air mix damper servo motor (rear RH*1 or LH*2) system malfunction
    A/M Servo Actual Pulse(F&R P)
    Air mix damper servo motor (rear RH*1 or LH*2) actual pulse / Min.: 128, Max.:383
    for LHD:
    1. MAX COLD: 161 (pulse)
    2. MAX HOT: 133 (pulse)
    for RHD:
    1. MAX COLD: 141 (pulse)
    2. MAX HOT: 169 (pulse)
    1. Displayed between 133 and 161 pulse (for LHD)
    2. Displayed between 141 and 169 pulse (for RHD)
    3. Air mix damper servo motor (rear RH*1 or LH*2) system malfunction
    Air Outlet Servo Pls (F&R D)
    Mode damper servo motor (rear) target pulse / Min.: 128, Max.: 383
    1. FACE: 137 (pulse)
    2. B/L: 156 (pulse)
    3. FOOT-R: 169 (pulse)
    4. FOOT-F: 186 (pulse)
    5. F/D: 195 (pulse)
    6. DEF: 207 (pulse)
    1. Displayed between 137 and 207 pulse
    2. Mode damper servo motor (rear) system malfunction
    A/O Servo Actual PIse(F&R D)
    Mode damper servo motor (rear) actual pulse / Min.: 128, Max.: 383
    1. FACE: 137 (pulse)
    2. B/L: 156 (pulse)
    3. FOOT-R: 169 (pulse)
    4. FOOT-F: 186 (pulse)
    5. F/D: 195 (pulse)
    6. DEF: 207 (pulse)
    1. Displayed between 137 and 207 pulse
    2. Mode damper servo motor (rear) system malfunction
    Room Temperature Sensor (RP)
    Rear room temperature sensor RH / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F)
    Actual rear room temperature for RH seat displayed
    Rear room temperature sensor RH system malfunction:
    1. Open in the circuit: -6.5°C (20.3°F)
    2. Short in the circuit: 57.25°C (135.05°F)
    Estimated Temperature (Rear D side)
    Rear driver side set temperature / MAX COLD: 17.5°C (63.5°F), MAX HOT: 32.5°C (90.5°F)
    Rear driver side actual set temperature displayed
    No. 2 air conditioning assembly system malfunction
    Estimated Temperature (Rear P side)
    Rear passenger side set temperature / MAX COLD: 17.5°C (63.5°F), MAX HOT: 32.5°C (90.5°F)
    Rear passenger side actual set temperature displayed
    No. 2 air conditioning assembly system malfunction
    A/O Damper DEF Pos(D side)
    DEF mode damper servo motor target pulse / Min.: 128, Max.: 383
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 199 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    1. Displayed between 134 and 245 pulse
    2. DEF mode damper servo motor system malfunction
    A/O Damper DEF Actual Pos(D)
    DEF mode damper servo motor actual pulse / Min.: 128, Max.: 383
    1. FACE1: 245 (pulse)
    2. FACE2: 237 (pulse)
    3. B/L1: 221 (pulse)
    4. B/L2: 209 (pulse)
    5. FOOT-O: 199 (pulse)
    6. FOOT-D: 199 (pulse)
    7. FOOT-R: 169 (pulse)
    8. FOOT-F: 169 (pulse)
    9. F/D: 146 (pulse)
    10. DEF: 134 (pulse)
    1. Displayed between 134 and 245 pulse
    2. DEF mode damper servo motor system malfunction
    A/M Servo Targ Pulse(Rear P)
    Rear air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.: 383
    for LHD:
    1. MAX COLD: 181 (pulse)
    2. MAX HOT: 136 (pulse)
    for RHD:
    1. MAX COLD: 137 (pulse)
    2. MAX HOT: 182 (pulse)
    1. Displayed between 136 and 181 pulse (for LHD)
    2. Displayed between 137 and 182 pulse (for RHD)
    3. Rear air mix damper servo motor RH*1 or LH*2 system malfunction
    A/M Servo Actual Pulse (Rear P)
    Rear air mix damper servo motor RH actual pulse / Min.: 128, Max.: 383
    for LHD:
    1. MAX COLD: 181 (pulse)
    2. MAX HOT: 136 (pulse)
    for RHD:
    1. MAX COLD: 137 (pulse)
    2. MAX HOT: 182 (pulse)
    1. Displayed between 136 and 181 pulse (for LHD)
    2. Displayed between 137 and 182 pulse (for RHD)
    3. Rear air mix damper servo motor RH*1 or LH*2 system malfunction
    Foot Duct Sensor (Rear D)
    Air duct temperature sensor LH*1 or RH*2 / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F)
    Cooler thermistor (duct sensor LH*1 or RH*2) displayed
    Cooler thermistor (duct sensor LH*1 or RH*2) system malfunction:
    1. Open in the circuit: -12.7°C (9.14°F)
    2. Short in the circuit: 76.55°C (169.79°F
    Foot Duct Sensor (Rear P)
    Air duct temperature sensor RH*1 or LH*2 / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F)
    Cooler thermistor (duct sensor RH*1 or LH*2) displayed
    Cooler thermistor (duct sensor RH*1 or LH*2) system malfunction:
    1. Open in the circuit: -12.7°C (9.14°F)
    2. Short in the circuit: 76.55°C (169.79°F
    IDLE UP/PWR HEAT Switch
    Idle up switch / ON, OFF
    ON: Idle up switch on
    OFF: Idle up switch off
    w/ Viscous Heater
    Refrigerant Gas Type
    Refrigerant gas type / R134a or 1234yf
    Refrigerant gas type displayed
    -
    Number of Trouble Codes
    Number of trouble codes / Min.: 0, Max.: 255
    Number of DTCs displayed
    -

    1. *1: for LHD
    2. *2: for RHD

    Engine
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/C Signal
    A/C signal / ON or OFF
    ON: A/C Switch on
    OFF: A/C Switch off
    -

ACTIVE TEST
HINT:
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
  1. Connect the GTS to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the GTS on.

  4. Enter the following menus: Body / Air Conditioner / Active Test.

  5. According to the display on the GTS, perform the Active Test.

    Air Conditioner
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -
    Heater Active Level
    Heater active level
    Min.: 0, Max.: 3
    -
    Magnetic Clutch Relay
    Magnetic clutch relay
    ON or OFF
    -
    Air Mix Servo Targ Pulse(D)
    Air mix damper servo motor LH*1 or RH*2 pulse
    Min.: 128, Max.: 383
    Operates between 136 to 218
    Air Mix Servo Targ Pulse(P)
    Air mix damper servo motor RH*1 or LH*" pulse
    Min.: 128, Max.: 383
    Operates between 136 to 218
    Air Outlet Servo Pulse (D)
    Mode damper servo motor LH Pulse
    Min.: 128, Max.: 383
    Operates between 136 to 245
    Air Inlet Damper Targ Pulse
    Mode damper servo motor (REC/FRS) pulse
    Min.: 128, Max.: 383
    Operates between 137 to 165
    Cool Air Bypass Pulse
    Cool air bypass damper servo motor pulse
    Min.: 128, Max.: 383
    Operates between 134 to 185
    Rear Blower Motor
    Rear blower motor
    Min.: 0, Max.: 31
    -
    Rear Air Mix Servo Targ Pulse
    Rear air mix damper servo motor LH*1 or RH*2 Pulse
    Min.: 128, Max.: 383
    1. Operates between 137 to 182 (for LHD)
    2. Operates between 136 to 181 (for RHD)
    Rear A/C Mag Valve
    Rear air conditioning magnetic valve
    ON or OFF
    -
    Air Outlet Servo Pulse (P)
    Mode damper servo motor RH*1 or LH*2 pulse
    Min.: 128, Max.: 383
    1. Operates between 134 to 245 (for LHD)
    2. Operates between 136 to 248 (for RHD)
    A/M Servo Puls(F&R D)
    Air mix damper servo motor (rear LH*1 or RH*2) pulse
    Min.: 128, Max.: 383
    1. Operates between 141 to 169 (for LHD)
    2. Operates between 133 to 161 (for RHD)
    A/M Servo Puls(F&R P)
    Air mix damper servo motor (rear RH*1 or LH*2) pulse
    Min.: 128, Max.: 383
    1. Operates between 133 to 161 (for LHD)
    2. Operates between 141 to 169 (for EHD)
    A/O Servo Pulse(F&R D)
    Mode damper servo motor (rear) pulse
    Min.: 128, Max.: 383
    Operates between 137 to 207
    A/O Servo Pulse(Rr D)
    Rear mode damper servo motor pulse
    Min.: 128, Max.: 383
    Operates between 135 to 211
    DEF A/O Servo Pulse(D)
    DEF mode damper servo motor pulse
    Min.: 128, Max.: 383
    Operates between 135 to 245
    Rear A/M Servo Pulse(P)
    Rear air mix damper servo motor RH*1 or LH*2 pulse
    Min.: 128, Max.: 383
    1. Operates between 136 to 181 (for LHD)
    2. Operates between 137 to 182 (for RHD)

    1. *1: for LHD
    2. *2: for RHD