Generator Inspection

Power Source Network. Land Cruiser. Urj200, 202 Grj200 Vdj200
3Ur-Fe Battery Charging. Land Cruiser. Urj200, 202 Grj200 Vdj200

  1. INSPECT GENERATOR ROTOR ASSEMBLY

  2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

Generator -- Inspection



1. INSPECT GENERATOR ROTOR ASSEMBLY


  1. Check the resistance.



      Land Cruiser. Urj200, 202 Grj200 Vdj200.3Ur-Fe Battery Charging.Charging System.Generator  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      1.5 to 1.9 Ω
      Text in Illustration
      *1
      Slip Ring
      If the result is not as specified, replace the generator rotor assembly.


    2. Land Cruiser. Urj200, 202 Grj200 Vdj200.3Ur-Fe Battery Charging.Charging System.Generator  Inspection
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Rotor core
      Always
      10 kΩ or higher
      Text in Illustration
      *1
      Slip Ring
      *2
      Rotor Core
      If the result is not as specified, replace the generator rotor assembly.


    Land Cruiser. Urj200, 202 Grj200 Vdj200.3Ur-Fe Battery Charging.Charging System.Generator  Inspection
  1. Using a vernier caliper, measure the slip ring diameter.

    Standard diameter:
    14.2 to 14.8 mm (0.559 to 0.583 in.)
    Minimum diameter:
    14.0 mm (0.551 in.)
    Text in Illustration
    *1
    Diameter
    If the diameter is less than the minimum, replace the generator rotor assembly.


    Land Cruiser. Urj200, 202 Grj200 Vdj200
  1. Check that the generator rotor bearing is not rough or worn.
    If necessary, replace the generator rotor assembly.



2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    Land Cruiser. Urj200, 202 Grj200 Vdj200.3Ur-Fe Battery Charging.Charging System.Generator  Inspection
  1. Using a vernier caliper, measure the brush length.

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)
    Minimum exposed length:
    4.5 mm (0.177 in.)
    Text in Illustration
    *1
    Length
    If the brush length is less than the minimum, replace the generator brush holder assembly.