Sfi System Fuel Injector Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK FUEL INJECTOR ASSEMBLY (POWER SOURCE)
INSPECT FUEL INJECTOR ASSEMBLY
CHECK HARNESS AND CONNECTOR (FUEL INJECTOR ASSEMBLY - ECM)
SFI SYSTEM - Fuel Injector Circuit |
DESCRIPTION
The fuel injector assemblies are located on the intake manifold. They inject fuel into the cylinders based on the signals from the ECM.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK FUEL INJECTOR ASSEMBLY (POWER SOURCE) |
Disconnect the fuel injector assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Cylinder
| Tester Connection
| Switch Condition
| Specified Condition
|
No. 1
| C5-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
No. 2
| C16-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
No. 3
| C7-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
No. 4
| C14-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
No. 5
| C9-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
No. 6
| C12-1 - Body ground
| Ignition switch ON
| 11 to 14 V
|
Text in Illustration*a
| Front view of wire harness connector (to Fuel Injector Assembly)
|
Turn the ignition switch off.
| REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION RELAY (IG2 MAIN) - FUEL INJECTOR ASSEMBLY) |
|
|
2.INSPECT FUEL INJECTOR ASSEMBLY |
Inspect the fuel injector assembly (Click here).
3.CHECK HARNESS AND CONNECTOR (FUEL INJECTOR ASSEMBLY - ECM) |
Disconnect the fuel injector assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDCylinder
| Tester Connection
| Condition
| Specified Condition
|
No. 1
| C5-2 - Body ground
| Always
| 10 kΩ or higher
|
C5-2 - C45-86 (#10)
| Always
| Below 1 Ω
|
No. 2
| C16-2 - Body ground
| Always
| 10 kΩ or higher
|
C16-2 - C45-109 (#20)
| Always
| Below 1 Ω
|
No. 3
| C7-2 - Body ground
| Always
| 10 kΩ or higher
|
C7-2 - C45-85 (#30)
| Always
| Below 1 Ω
|
No. 4
| C14-2 - Body ground
| Always
| 10 kΩ or higher
|
C14-2 - C45-108 (#40)
| Always
| Below 1 Ω
|
No. 5
| C9-2 - Body ground
| Always
| 10 kΩ or higher
|
C9-2 - C45-84 (#50)
| Always
| Below 1 Ω
|
No. 6
| C12-2 - Body ground
| Always
| 10 kΩ or higher
|
C12-2 - C45-107 (#60)
| Always
| Below 1 Ω
|
for RHDCylinder
| Tester Connection
| Condition
| Specified Condition
|
No. 1
| C5-2 - Body ground
| Always
| 10 kΩ or higher
|
C5-2 - C46-86 (#10)
| Always
| Below 1 Ω
|
No. 2
| C16-2 - Body ground
| Always
| 10 kΩ or higher
|
C16-2 - C46-109 (#20)
| Always
| Below 1 Ω
|
No. 3
| C7-2 - Body ground
| Always
| 10 kΩ or higher
|
C7-2 - C46-85 (#30)
| Always
| Below 1 Ω
|
No. 4
| C14-2 - Body ground
| Always
| 10 kΩ or higher
|
C14-2 - C46-108 (#40)
| Always
| Below 1 Ω
|
No. 5
| C9-2 - Body ground
| Always
| 10 kΩ or higher
|
C9-2 - C46-84 (#50)
| Always
| Below 1 Ω
|
No. 6
| C12-2 - Body ground
| Always
| 10 kΩ or higher
|
C12-2 - C46-107 (#60)
| Always
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|