Variable Gear Ratio Steering System Data List / Active Test

Steering. Land Cruiser. Urj200, 202 Grj200 Vdj200
Variable Gear Ratio Steering. Land Cruiser. Urj200, 202 Grj200 Vdj200
  1. DATA LIST

  1. Abnormal Operation History

Variable Gear Ratio Steering System -- Data List / Active Test


HINT:
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

DATA LIST
  1. Turn the engine switch off.

  2. Connect the GTS to the DLC3.

  3. Turn the engine switch on (IG).

  4. Turn the GTS on.

  5. Enter the following menus: Chassis / VGRS / Data List.

  6. According to the display on the GTS, read the Data List.

    VGRS
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Steering Angle
    Steering angle/
    Min.: -1638.40 deg
    Max.: 1638.35 deg
    -600 to 600 deg
    -
    Steering Angle Changing Speed
    Steering angle changing speed/
    Min.: -1638.40 deg/s
    Max.: 1638.35 deg/s
    -1146 to 1146 deg/s
    -
    Vehicle Speed
    Vehicle speed/
    Min.: 0.00 km/h (0 mph)
    Max.: 327.67 km/h (203 mph)
    Actual vehicle speed
    -
    Starting Status
    Starting status/
    Stop or Starting-up
    Engine stopped: Stop Engine running: Starting-up
    -
    IG Power Supply Voltage
    IG power supply voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    11 to 14 V
    -
    PIG Power Supply Voltage
    PIG power supply voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    11 to 14 V
    -
    Power Supply Status
    Power supply status/
    Normal, N Pos Stop, Cur Pos Stop or Prompt Stop
    Normal
    -
    System Heavily-loaded Status
    System heavily-loaded status/
    ON or OFF
    OFF
    -
    ECU Substrate Temperature
    ECU substrate temperature/
    Min.: -256.00°C (-428°F)
    Max.: 255.99°C (492°F)
    Within 20°C (68°F) of ambient temperature
    -
    Motor Temperature (ECU Calculated Value)
    Motor temperature/
    Min.: -256.00°C (-428°F)
    Max.: 255.99°C (492°F)
    Within 20°C (68°F) of ambient temperature
    -
    Ambient Temperature
    Ambient temperature/
    Min.: -40°C (-40°F)
    Max.: 50°C (122°F)
    Same as ambient temperature
    -
    System Overheat Status
    System overheat status/
    Normal, Overheat-Weak, Overheat-Mid or Overheat-Strong
    Normal
    -
    ECU Substrate Temperature (ECU Calculated Value)
    ECU substrate temperature/
    Min.: -256.00°C (-428°F)
    Max.: 255.99°C (492°F)
    -40 to 70°C (-40 to 158°F)
    -
    Wheel Angle (SIL Communication)
    Wheel angle (SIL communication/
    Min.: -1638.40 deg
    Max.: 1638.35 deg
    -600 to 600 deg
    -
    Wheel Angle (CAN Communication)
    Wheel angle (CAN communication)/
    Min.: -1638.40 deg
    Max.: 1638.35 deg
    -600 to 600 deg
    -
    Steering Angle Sensor Communication Protocol
    Steering sensor communication protocol/
    Calc Val Fix, SIL or CAN
    SIL
    -
    Direct Advance Wheel Angle
    Direct advance wheel angle/
    Min.: -1638.40 deg
    Max.: 1638.35 deg
    -10.5 to 10.5 deg
    -
    Direct Advance Wheel Angle Status
    Direct advance wheel angle status/
    Delete, Temp Val or Fixed Val
    Fixed Val
    NOTICE:
    This data must be "Fixed Val" before proceeding with any steering adjustment. If "Delete" or "Temp Val" is displayed, perform the steering sensor initialization procedure. If the steering actuator assembly or VGRS ECU (steering control ECU) has been replaced, perform VGRS system calibration (steering angle adjustment).
    Motor Resolver Electrical Angle
    Motor resolver electrical angle/
    Min.: 0.00 deg
    Max.: 359.99 deg
    0.00 to 359.99 deg
    -
    Changing Amount of Motor Resolver Electrical Angle
    Changing amount of motor resolver electrical angle/
    Min.: -180.00 deg
    Max.: 179.99 deg
    -46 to 46 deg
    -
    Motor Resolver SIN Phase Shaped Width
    Motor resolver SIN phase amplitude/
    Min.: -5.00 V
    Max.: 4.99 V
    -4.1 to 4.1 V
    -
    Motor Resolver SIN Phase Offset
    Motor resolver SIN phase offset/
    Min.: 0.00 V
    Max.: 19.99 V
    5 to 15 V
    -
    Motor Resolver COS Phase Shaped Width
    Motor resolver COS phase amplitude/
    Min.: -5.00 V
    Max.: 4.99 V
    -4.1 to 4.1 V
    -
    Motor Resolver COS Phase Offset
    Motor resolver COS phase offset/
    Min.: 0.00 V
    Max.: 19.99 V
    5 to 15 V
    -
    Motor Resolver Shaped Width Squared Sum
    Sum of squares of motor resolver amplitudes/
    Min.: 0.00 V^2
    Max.: 25.00 V^2
    1.4 to 16.6 V^2
    -
    Deep Groove Electrical Angle Position
    Deep groove electrical angle position/
    Min.: 0.00 deg
    Max.: 359.99 deg
    75 to 145 deg
    -
    Neutral Position Calibration Status
    Neutral position calibration status/
    Incmpl or Cmpl
    Cmpl
    -
    Actuator Target Angle
    Actuator target angle/
    Min.: -512.00 deg
    Max.: 511.98 deg
    -150 to 150 deg
    -
    Actuator Angle
    Actuator angle/
    Min.: -512.00 deg
    Max.: 511.98 deg
    -150 to 150 deg
    -
    Pinion Angle Status
    Pinion angle status/
    Invalid or Valid
    Valid
    -
    Pinion Angle
    Pinion angle/
    Min.: -2048.00 deg
    Max.: 2047.93 deg
    -600 to 600 deg
    -
    Motor U Phase Voltage
    Motor U phase voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    0 to 14 V
    -
    Motor V Phase Voltage
    Motor V phase voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    0 to 14 V
    -
    Motor W Phase Voltage
    Motor W phase voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    0 to 14 V
    -
    Motor U Phase Current
    Motor U phase current/
    Min.: -256.00 A
    Max.: 255.99 A
    -75 to 75 A
    -
    Motor V Phase Current
    Motor V phase current/
    Min.: -256.00 A
    Max.: 255.99 A
    -75 to 75 A
    -
    Motor W Phase Current
    Motor W phase current/
    Min.: -256.00 A
    Max.: 255.99 A
    -75 to 75 A
    -
    Motor U Phase Duty
    Motor U phase duty/
    Min.: 0.00 %
    Max.: 100.00 %
    6 to 94 %
    -
    Motor V Phase Duty
    Motor V phase duty/
    Min.: 0.00 %
    Max.: 100.00 %
    6 to 94 %
    -
    Motor W Phase Duty
    Motor W phase duty/
    Min.: 0.00 %
    Max.: 100.00 %
    6 to 94 %
    -
    PIG Current
    PIG current/
    Min.: -256.00 A
    Max.: 255.99 A
    -50 to 50 A
    -
    Motor Rotation Speed
    Motor rotation speed/
    Min.: -32768 deg/s
    Max.: 32767 deg/s
    -17190 to 17190 deg/s
    -
    Lock Solenoid Voltage
    Lock solenoid voltage/
    Min.: 0.00 V
    Max.: 255.99 V
    0 to 14 V
    -
    Lock Solenoid Duty
    Lock solenoid duty/
    Min.: 0 %
    Max.: 100 %
    0 to 100 %
    -
    Actuator Operation Amount
    Actuator operation amount/
    Too Little, Normal, Malfunction or Too Much
    Normal
    -
    Number of DTC
    Number of DTCs recorded/
    Min.: 0
    Max.: 255
    0
    -


Abnormal Operation History
  1. Turn the engine switch off.

  2. Connect the GTS to the DLC3.

  3. Turn the engine switch on (IG).

  4. Turn the GTS on.

  5. Enter the following menus: Chassis / VGRS / Data List.

  6. According to the display on the GTS, read the Abnormal Operation History.

    VGRS
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Limited Control Count (Overheat-Weak)
    Limited control count (overheat-weak)/
    Min.: 0
    Max.: 255
    -
    The number of times that overheat status of VGRS became "Overheat-Weak" and then the control was limited.
    Limited Control Count (Overheat-Mid)
    Limited control count (overheat-mid)/
    Min.: 0
    Max.: 255
    -
    The number of times that overheat status of VGRS became "Overheat-Mid" and then the control was limited.
    Limited Control Count (Overheat-Strong)
    Limited control count (overheat-strong)/
    Min.: 0
    Max.: 255
    -
    The number of times that overheat status of VGRS became "Overheat-Strong" and then the control was limited.
    N Pos Stop Control Count
    N pos stop control count/
    Min.: 0
    Max.: 255
    -
    The number of times that power supply status to VGRS became "N Pos Stop" and then the control in "N Pos Stop" happened.
    Cur Pos Stop Control Count
    Cur pos stop control count/
    Min.: 0
    Max.: 255
    -
    The number of times that power supply status to VGRS became "Cur Pos Stop" and then the control in "Cur Pos Stop" happened.
    Prompt Stop Control Count
    Prompt stop control count/
    Min.: 0
    Max.: 255
    -
    The number of times that power supply status to VGRS became "Prompt Stop" and then the control in "Prompt Stop" happened.
    Limited Control Count (System Heavily-loaded)
    Limited control count (system heavily-loaded)/
    Min.: 0
    Max.: 255
    -
    The number of times that VGRS system became heavily-loaded and then the control was limited.