Dtc P0748 Pressure Control Solenoid A Electrical
Drivetrain. Land Cruiser. Urj200, 202 Grj200 Vdj200
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL1 - TCM)
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
INSPECT SHIFT SOLENOID VALVE SL1
DTC P0748 Pressure Control Solenoid "A" Electrical |
DESCRIPTION
Based on the ON-OFF combinations of the shift solenoid valve SL1, SL2, SL3, SL4 and SL5, the TCM performs gear shifts from 1st gear to 8th gear.If a circuit related to a solenoid valve is open or shorted, the TCM uses the fail-safe function to turn other solenoid valves ON or OFF. If all solenoid valves are malfunctioning, only the mechanical fluid pressure circuit will function and some manual operation will be possible. If an open or short has occurred, the TCM cuts power to the malfunctioning solenoid valve.- HINT:
- The following table shows normal operation of the shift solenoid valve SL1 when the shift lever is in D.
Shift Solenoid Valve Operation:Gear
| 1st
| 2nd
| 3rd
| 4th
| 5th
| 6th
| 7th
| 8th
|
Shift Solenoid Valve SL1
| ON
| ON
| ON
| ON
| ON
| OFF
| OFF
| OFF
|
DTC No.
| DTC Detection Condition
- Diagnosis Condition
- Malfunction Status
- Malfunction Time
- Other
| Trouble Area
|
P0748
| - Driving so that gear changes occur
- Shift solenoid valve SL1 circuit is open or shorted
- 2 seconds
- 1-trip detection logic
| - Shift solenoid valve SL1
- Transmission wire
- Harness or connector
- TCM
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores a DTC. The TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off. In case of an open or short circuit, the TCM stops sending current to the open or short circuited solenoid.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Perform registration and/or initialization when parts related to the automatic transmission are replaced (Click here).
- HINT:
- After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
- Perform the D Position Shift Test in Road Test (Click here).
- Check for DTCs again (Click here).
1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL1 - TCM) |
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A80-9 (SL1+) - A80-8 (SL1-)
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
A80-9 (SL1+) or A80-8 (SL1-) - Body ground
| Always
| 10 kΩ or higher
|
Text in Illustration*a
| Rear view of wire harness connector (to TCM)
|
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the C171 transmission wire connector.
Disconnect the A80 TCM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
C171-25 (SL1+) - A80-9 (SL1+)
| Always
| Below 1 Ω
|
C171-26 (SL1-) - A80-8 (SL1-)
| Always
| Below 1 Ω
|
C171-25 (SL1+) or A80-9 (SL1+) - Body ground
| Always
| 10 kΩ or higher
|
C171-26 (SL1-) or A80-8 (SL1-) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE SL1 |
Remove the shift solenoid valve SL1 (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Terminal 1 of the shift solenoid valve SL1 - Terminal 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
| Valve moves and makes an operating noise
|
Text in Illustration*1
| Shift Solenoid Valves SL1
|