Engine Hybrid System. Yaris. Ncp93, 131
1Nz-Fe Cooling. Yaris. Ncp93, 131
Radiator (For Hatchback) -- On-Vehicle Inspection |
1. CHECK WATER FILLER CAP SUB-ASSEMBLY |
![]() |
Measure the valve opening pressure.
If there are water stains or foreign matter on rubber packing 1, 2 or 3, clean the part(s) with water and finger scouring.
Check that rubber packings 1, 2 and 3 are not deformed, cracked or swollen.
Check that rubber packings 3 and 4 are not stuck together.
Apply engine coolant to rubber packings 2 and 3 before using the radiator cap tester.
When using the cap tester, tilt it to more than 30 degrees.
Pump the cap tester several times, and check the maximum pressure *1.
- Pumping speed:
- 1 pump per second
- Judgment criteria:
Item Specified Condition Standard value
(for brand-new cap)93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) Minimum standard value
(after using cap)78.5 kPa (0.8 kgf/cm2, 11.4 psi)
If the maximum pressure is less than the specified pressure for the minimum standard valve, replace the water filler cap sub-assembly.Text in Illustration *1 Radiator Cap Tester *2 Water Filler Cap Sub-Assembly *a 30° or more
2. INSPECT FINS FOR BLOCKAGE |
![]() |
If the fins are clogged, wash them with water or a steam cleaner and dry them with compressed air.
- NOTICE:
- To avoid damaging the fins, the injection direction should be at right angles to the core surface.
- If the steam cleaner is too close to the core, there is a possibility of damaging the fins, so keep to the following injection distances.
Injection Pressure
kPa (kgf/cm2, psi)Injection Distance
mm (in.)2.942 to 4.903
(30 to 50, 427 to 711)300 (11.811) 4.903 to 7.845
(50 to 80, 711 to 1.138)500 (19.685) - If the fins are bent, straighten them with a screwdriver or pliers.
- Do not expose electronic components to water.