Dtc B1451/51 Compressor Solenoid Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING TECHSTREAM (REGULATOR CONTROL CURRENT)
INSPECT COMPRESSOR AND PULLEY
CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - AIR CONDITIONING AMPLIFIER)
CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - BODY GROUND)
DTC B1451/51 Compressor Solenoid Circuit |
DESCRIPTION
In this circuit, the compressor receives a refrigerant compression demand signal from the air conditioning amplifier.Based on this signal, the compressor changes the degree of refrigerant compression.DTC No.
| DTC Detection Condition
| Trouble Area
|
B1451/51
| Open or short in solenoid of externally changeable compressor circuit
| - Compressor and pulley
- Harness and connector between air conditioning amplifier and compressor and pulley
- Air conditioning amplifier
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING TECHSTREAM (REGULATOR CONTROL CURRENT) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Select the following menus: Body Electrical / Air Conditioner / Data List /
According to the display on tester, read the "Data List".
- Data List / Air Conditioner:
Tester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Regulator Control Current
| Regulator control current / Min.: 0 A Max.: 0.997 A
| Value changes between 0 A and 0.997 A in accordance with compressor and pulley operation
| -
|
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
| Proceed to
|
NG
| A
|
OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE)
| B
|
OK (When troubleshooting according to the DTC)
| C
|
2.INSPECT COMPRESSOR AND PULLEY |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
- Standard resistance:
Tester Connection
| Specified Condition
|
C8-1 - C8-2
| 10.1 to 11.1 Ω at 25°C (77°F)
|
Reconnect the compressor and pulley connector.
3.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - AIR CONDITIONING AMPLIFIER) |
Disconnect the C8 compressor and pulley connector.
Disconnect the E8 air conditioning amplifier connector.
Measure the resistance.
- Standard resistance:
Tester Connection
| Specified Condition
|
C8-1 - E8-7 (SOL+)
| Below 1 Ω
|
C8-1 - Body ground
| 10 kΩ or higher
|
Reconnect the compressor and pulley connector.
Reconnect the air conditioning amplifier connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.CHECK HARNESS AND CONNECTOR (COMPRESSOR AND PULLEY - BODY GROUND) |
Disconnect the C8 compressor and pulley connector.
Measure the resistance.
- Standard resistance:
Tester Connection
| Specified Condition
|
C8-2 - Body ground
| Below 1 Ω
|
Reconnect the compressor and pulley connector.
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|