Dtc B1442/42 Air Inlet Damper Control Servo Motor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING INTELLIGENT TESTER (A/I DAMP TARG PLS)
REPLACE AIR INLET CONTROL SERVO MOTOR
DTC B1442/42 Air Inlet Damper Control Servo Motor Circuit |
DESCRIPTION
The damper servo (air inlet control) sends pulse signals to indicate the damper position to the air conditioning amplifier. The air conditioning amplifier activates the motor (normal or reverse) based on these signals to move the air inlet control damper to the appropriate position, which controls the intake air settings (FRESH, FRESH / RECIRCULATION and RECIRCULATION).- HINT:
- Confirm that there are no mechanical problems because this DTC can be output when either a damper link or damper is mechanically locked.
DTC No.
| DTC Detection Condition
| Trouble Area
|
B1442/42
| Air inlet damper position does not change even if air conditioning amplifier operates air inlet damper control servo motor
| - Air inlet control servo motor
- Air conditioning harness
- Air conditioning amplifier
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING INTELLIGENT TESTER (A/I DAMP TARG PLS) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the items below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
| Measurement Item / Display (Range)
| Normal Condition
| Diagnostic Note
|
A/I Damp Targ Pls
| Air inlet damper target pulse / for LHD Min.: 7, Max.: 19 for RHD Min.: 7, Max.: 25
| for LHD - RECIRCULATION: 19 (pulse)
- FRESH: 7 (pulse)
for RHD - RECIRCULATION: 7 (pulse)
- FRESH: 25 (pulse)
| -
|
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
| Proceed to
|
NG
| A
|
OK (Checking from PROBLEM SYMPTOMS TABLE)
| B
|
OK (Checking from DTC)
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|
|
| REPLACE AIR CONDITIONING AMPLIFIER |
|
|
2.REPLACE AIR INLET CONTROL SERVO MOTOR |
- HINT:
- Since the servo motor cannot be tested when it is removed from the vehicle, replace the servo motor with a normal one and check that the condition returns to normal.
- OK:
- Same problem does not occur.
| REPAIR OR REPLACE AIR CONDITIONING HARNESS |
|
|